Optimum Design of Converter and Circuit Breaker in High Voltage DC System
نویسندگان
چکیده
منابع مشابه
High voltage gain DC-DC resonant converter
In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...
متن کاملHigh voltage gain DC-DC resonant converter
In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...
متن کاملhigh voltage gain dc-dc resonant converter
in this paper, a dc-dc resonant converter with high voltage gain and small size is studied. to reduce the size and weight of this converter, the operating frequency should be as high as possible. in this research, the frequency changes from 120 to 200 khz. due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. resonant converters are su...
متن کاملHigh Frequency Dc-dc Converter Design Using Zero Voltage Switching
Resonant mode conversion techniques are used nowadays to improve pulse width modulated dcdc converters. Moreover the quest for ever smaller 50 to 500 watts dc-dc switching supplies has led to the development of circuits that operates in 500 KHz -1 MHz range and above. Since the parasitic elements that normally present in a power circuit can be very significant at this frequency, most of the wor...
متن کاملA Protection Circuit for DC-DC Converter with Voltage Doubler
This paper proposes a method to obtain a protected voltage gain by employing a protection circuit for the voltage doubler or multiplier circuit in an isolated tyde DC-DC Converter. The entire set up consists of a phase shift converter with a protected bridge/voltage doubler rectifier on the output side. The operating frequency of the phase shift converter is 20-25kHz (depending on the requireme...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Materials Science and Engineering
سال: 2019
ISSN: 1757-899X
DOI: 10.1088/1757-899x/631/4/042033