Optimized Readout Methods of Silicon Drift Detectors for High Resolution Spectroscopy in Micro-Beam Analysis
نویسندگان
چکیده
منابع مشابه
Silicon Drift Detectors for High Resolution, High Count Rate X-ray Spectroscopy at Room Temperature
Silicon Drift Detectors (SDDs) consist of a fully depleted volume in which an electric field drives signal charges to a small sized anode. Due to their topology SDDs combine a large sensitive area with a small output capacitance. In an advanced SDD version for X-ray spectroscopy designed and fabricated at the MPI semiconductor laboratory the input transistor of the amplifying electronics has be...
متن کاملAnalysis of Background Events in Silicon Drift Detectors
Measurements of the energy resolution and the peak-to-background ratio of a Silicon Drift Detector at several positions and biasing voltages are performed. The origins of events with partial charge collection, which contribute to the background, are identified. A model describing the different mechanisms and the spatial distribution of partial events is developed. By optimizing the biasing volt...
متن کاملAvalanche Amplification in Silicon Drift Detectors
A novel device which combines advantages of Silicon Drift Detector and Silicon Avalanche Diode on the same silicon wafer is proposed. Avalanche ampliication is applied to cloud of drifting electrons in order to improve detection of radiation with low energy deposition coeecient. Principle and optimal conditions for the operation of this new detector based on Avalanche Ampliier are discussed.
متن کاملTime-Optimized High-Resolution Readout-Segmented Diffusion Tensor Imaging
Readout-segmented echo planar imaging with 2D navigator-based reacquisition is an uprising technique enabling the sampling of high-resolution diffusion images with reduced susceptibility artifacts. However, low signal from the small voxels and long scan times hamper the clinical applicability. Therefore, we introduce a regularization algorithm based on total variation that is applied directly o...
متن کاملSignal-to-Noise in Silicon Microstrip Detectors with Binary Readout
We report the results of a beam test using double-sided ACcoupled silicon microstrip detectors with binary readout, i.e., a readout where the signals are discriminated in the front-end electronics and only the hit location as kept. For strip pitch between 50μm and 200μm, we determine the efficiency and the noise background as function of threshold setting. This allows us to reconstruct the Land...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2005
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927605506056