Optical Parameter Dependence of Fluorescence Correlation Spectrometry without Using Magnification Tools

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical parameter dependence of fluorescence correlation spectrometry without using magnification tools.

The performance of fluorescence correlation spectrometry (FCS) was examined for studying the solutions suspended with the fluorescent particles of various sizes from 50 nm to 10 microm in diameter and for different sizes of pinholes: the particles were made to move by simply stirring the solution in the quartz fluorescence cuvette. Without using any magnification tool for the optical image, thi...

متن کامل

Determining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry

The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method,  and the formation of beads. Certified reference bauxite samples were used for the cali...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

High-contrast fluorescence imaging based on the polarization dependence of the fluorescence enhancement using an optical interference mirror slide.

High-contrast fluorescence imaging using an optical interference mirror (OIM) slide that enhances the fluorescence from a fluorophore located on top of the OIM surface is reported. To enhance the fluorescence and reduce the background light of the OIM, transverse-electric-polarized excitation light was used as incident light, and the transverse-magnetic-polarized fluorescence signal was detecte...

متن کامل

Optical Calibration of a Submicrometer Magnification Standard

The calibration of a new submicrometer magnification standard for electron microscopes is described. The new standard is based on the width of a thin thermal-oxide film sandwiched between a silicon single-crystal substrate and a polysilicon capping layer. The calibration is based on an ellipsometric measurement of the oxide thickness before the polysilicon layer is deposited on the oxide. The u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 2007

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.23.1237