Ocular Surface Displacement with and without Contact Lenses during Non-Contact Tonometry

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Ocular Surface Displacement with and without Contact Lenses during Non-Contact Tonometry

PURPOSE To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs). METHODS One eye each in 21 subjects was studied. The cornea was photographed usin...

متن کامل

Non-contact tonometry in the postoperative eye.

The Keeler Pulsair non-contact tonometer was compared with the Goldmann applanation tonometer in a series of 48 eyes after operation. A correlation coefficient of 0.92 (p less than 0.001) was found between the two instruments, with the Pulsair having a statistically significant tendency to overread the Goldmann slightly in this situation. The Pulsair was, however, shown to be effective in the i...

متن کامل

Limitations of the ocular wavefront correction with contact lenses

We analyze theoretically, by means of both computer simulations and laboratory experiments, the limitations of correcting aberrations with ideal customized contact lenses. Four experiments are presented: In the first one, we have analyzed the limitations of a static correction on the dynamic wavefront. In the second one, we studied the rotations of a contact lens on the eye using an optical met...

متن کامل

Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

BACKGROUND The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted D...

متن کامل

Tear film surface quality with rigid and soft contact lenses.

OBJECTIVES The aim of this study was to measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hrs) use of rigid and soft contact lenses. METHODS A group of 14 subjects wore 3 different types of contact lenses on 3 different nonconsecutive days (order randomized) in 1 eye only. The subjects were screened to exclude those with dry eye. The lense...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: PLoS ONE

سال: 2014

ISSN: 1932-6203

DOI: 10.1371/journal.pone.0096066