Numerical Simulation of the Blast Resistance of SPUA Retrofitted CMU Masonry Walls

نویسندگان

چکیده

Through numerical simulation, the blast-resistant performance of spray polyurea elastomer (SPUA) retrofitted concrete masonry unit (CMU) infill walls under far-range blast loading was studied. From an engineering perspective, effects boundary conditions and thickness a SPUA layer on enhancing resistance are discussed, SPUA-retrofitted grouted CMU compared. It is concluded that constraint anchorage length have limited improvement wall; can significantly improve wall as increases. In addition, retrofitting shows relatively better to reinforce walls.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blast Resistance of Frp Retrofitted Un-Reinforced Masonry (URM) Walls With and Without Arching Action

9 1 TMS Member/Assistant Professor of Civil, Architectural, and Environmental Engineering, University of MissouriRolla, Rolla, MO 65401 2 TMS Member/Professor of Civil, Architectural, and Environmental Engineering, Univ. of Missouri-Rolla, Rolla, MO 65401 3 Former Graduate Research Assistant, University of Missouri-Rolla, Rolla, MO 65401 Blast Resistance of Frp Retrofitted Un-Reinforced Masonry...

متن کامل

Simulation of Masonry Beams Retrofitted with Engineered Cementitious Composites

A thin layer of ductile fiber-reinforced mortar material referred to as Engineered Cementitious Composites, or ECC has been experimentally investigated as a seismic retrofit for unreinforced masonry infill walls in non-ductile reinforced concrete frames. Compression tests of masonry prisms retrofitted with 13mm of ECC were conducted representing the compression strut of a masonry infill under i...

متن کامل

Resistance of Concrete Masonry Walls with Membrane Catcher Systems Subjected to Blast Loading

This paper describes a methodology for analyzing the impulse pressure response of unreinforced concrete masonry walls that have been retrofitted with membranes that are not bonded to the masonry (catcher systems). Membrane catcher systems can be used to protect building occupants from secondary debris resulting from blast pressure, and the effectiveness of systems comprising polymers, composite...

متن کامل

Blast Design of Reinforced Concrete and Masonry Components Retrofitted with Frp

Fiber-reinforced polymer (FRP) products are used as an alternative to traditional methods for strengthening and retrofitting concrete and masonry structures to resist blast loads. The development and experimental validation of a methodology for modeling the response of blast loaded concrete and masonry structural components retrofitted with FRP, as well as corresponding response criteria, is im...

متن کامل

Masonry Infill Walls under Blast Loading Using Confined Underwater Blast Wave Generators (wbwg)

The vulnerability of the masonry envelop under blast loading is considered critical due to the risk of loss of lives. The dynamic behaviour of masonry infill walls subjected to dynamic out-of-plane loading was experimentally investigated in this work. Using confined underwater blast wave generators (WBWG), applying the extremely high rate conversion of the explosive detonation energy into the k...

متن کامل