Numerical Calculation of Overhead Power Lines Dynamics

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lightning Protection of Overhead Power Distribution Lines

Distribution lines are often located in areas with high ground flash densities, being therefore subject to lightning-caused power interruptions. This paper presents an overview of the various types of lightning overvoltages that can arise on overhead power distribution networks, as well as typical voltage waveforms. The effectivenesses of the most important methods for mitigating such overvolta...

متن کامل

Power transmission capacity upgrade of overhead lines

Electric power consumption, has been increasing uninterruptedly, being this increase specially accelerated in the last years. New power generators are been built, the installed power increases each year, thus it is necessary a way to transmit the bulk energy. Nowadays electric lines are saturated, they are reaching critical values of ampacity and sag. Therefore building new lines is necessary t...

متن کامل

On Calculation of the Ground Transient Resistance of Overhead Lines

A constraint on the calculation of the ground transient resistance of overhead lines for small values of time is pointed out. The method for overcoming this constraint is proposed. The source of the ground transient resistance singularity is the low-frequency approximation of the ground impedance. It is shown that the ground transient resistance is not singular for t! 0 if it is calculated with...

متن کامل

Emissions of electromagnetic fields caused by sagged overhead power lines

Nowadays people became aware of the overhead lines and their emissions of electromagnetic fields. This work presents a method for calculation of the electric field strength and magnetic field density caused by the overhead power lines at the ground level. The method considers the conductor sagging. It is shown that the sagged conductors can be replaced with the properly placed straight conducto...

متن کامل

A generalized model for the calculation of the impedances and admittances of overhead power lines above stratified earth

A general formulation for the determination of the influence of imperfect earth on overhead transmission line impedances and admittances is presented in this paper. The resulting model can be used in the simulationof electromagnetic transients in casesof two-layer earthover awide frequency range, covering most fast transient phenomena of power engineering interest. The propagation characteristi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Strojnícky casopis – Journal of Mechanical Engineering

سال: 2016

ISSN: 2450-5471

DOI: 10.1515/scjme-2016-0014