Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood Pressure Estimation based on Pulse Transit Time and Compensation of Vertical Position

A chronically high blood pressure (BP) may lead to arteriosclerosis and consequently is a risk factor for apoplectic stroke and cardiac infarction – the main death causes in industrial countries. Hence, blood pressure recently has become one of the most relevant parameters for the assessment of a patients’ health status. For the purpose of a continuous monitoring of cardiovascular patients, we ...

متن کامل

Pulse transit time and blood pressure during cardiopulmonary exercise tests.

Pulse transit time (PTT), the interval between ventricular electrical activity and peripheral pulse wave, is assumed to be a surrogate marker for blood pressure (BP) changes. The objective of this study was to analyze PTT and its relation to BP during cardiopulmonary exercise tests (CPET). In 20 patients (mean age 51+/-18.4 years), ECG and finger-photoplethysmography were continuously recorded ...

متن کامل

Methods for reliable estimation of pulse transit time and blood pressure variations using smartphone sensors

Hypertension is known to affect around one third of adults globally and early diagnosis is essential to reduce the effects of this affliction. Today’s Blood Pressure (BP) monitoring cuffs are obtrusive and inconvenient for performing regular measurements, and continuous non-invasive blood pressure devices are too complex and expensive for ambulatory use. Hence, there is a strong need for afford...

متن کامل

Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation.

Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BioMedical Engineering OnLine

سال: 2018

ISSN: 1475-925X

DOI: 10.1186/s12938-018-0510-8