Novel approach to determination of Fe(II) using a flow system with direct-injection detector
نویسندگان
چکیده
منابع مشابه
Determination of nitrite by flow injection spectrophotometry using a home-made flow cell detector.
A simple, rapid, low cost and accurate determination using flow injection spectrophotometry with a home made flow cell detector, in combination with green LED and photodiode, had been developed for nitrite based on the Griess-Saltzman reaction, measuring the absorbance at 525 nm. The proposed system is able to monitor nitrite in freshwater samples at a throughput of 60 samples per hour with a r...
متن کاملBromide Determination in Pharmaceutical Preparations Using Indirect Gas-Diffusion Flow Injection Method with Amperometric Detector
The indirect gas-diffusion flow injection method (FI) was modified, optimized and successfully applied to bromide determination in various samples such as active substances, drugs, organic substances and water samples. The method is based on the oxidation of bromide to bromine in acidic medium, which diffuses through PTFe membrane into the acceptor flow that carried bromine to the amperometric ...
متن کاملSequential flow injection determination of chlorine species using a triiodide-selective electrode detector.
A flow injection analysis (FIA) method for the determination of four residual chlorine species, namely combined available chlorine (CAC), free available chlorine (FAC), total available chlorine (TAC) and chlorite (ClO2-) was developed using a flow-through triiodide-selective electrode as a detector. An important strategy of speciation studies utilized the kinetic discrimination of reactions bet...
متن کاملFlow injection potentiometric determination of Fe ( III ) using a fluoride - selective electrode as detector *
Flow injection analysis (FIA) system incorporating a fluoride ion-selective electrode (FISE) as detector is described. Laboratory-built cascade flow cell equipped with FISE and reference electrode is used for flow injection potentiometric determination of Fe(III) based on monitoring of the formation of FeF2 in acid solution. Under optimized flow conditions (4.0 mL min–1, 300 μL samples, 10–5 mo...
متن کاملFlow injection analysis of nitrogen dioxide using a galvanic detector
A flow injection configuration (FIA) based on a galvanic detector for the determination of nitrogen dioxide is described. The gaseous sample is directly injected into a gaseous carrier. The sample is transported toward the detector. The steady state measurements are not required to obtain the reproducible peak signals. The features of FIA are compared with that of continuous flow monitoring app...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Monatshefte für Chemie - Chemical Monthly
سال: 2020
ISSN: 0026-9247,1434-4475
DOI: 10.1007/s00706-020-02649-8