A simple, relatively precise, and clinically applicable indirect method of determining relative cardiac output is presented. The principle involved is a modification of the dye-dilution principle and is performed by external monitoring of intravenously injected radioiodinated serum albumin combined with a standard detecting and recording device. This procedure was performed serially before and ...
متن کاملCardiac Output Response to Exercise in Patients with Inferior Vena
Studies were carried out to determine whether hemodynamic alterations may follow inferior vena caval (IVC) ligation. Five patients, aged 29 to 49 years, who had been operated upon 2 to 5 years previously, and five normal controls, aged 39 to 44 years, were studied at rest and during graded submaximal treadmill exercise. There were no significant differences in heart rate, right atrial pressure,...
متن کاملCardiac output response to exercise in chronic cardiac failure patients.
The purpose of this study was to investigate the precise pattern of stroke volume (SV) response during exercise in patients with chronic heart failure (CHF) compared with age-matched controls. Fourteen patients with CHF and 7 controls performed symptom-limited bicycle exercise testing with respiratory gas exchange measurement. Patients were classified into group A (n = 7) with peak VO2 ≥ 18.0 m...
متن کاملCardiac Output of Men and Dogs Measured by in vivo Analysis of Iodinated (I) Human Serum Albumin
THE first published effort to record the intensity of radioactivity as a function of time over the heart following a single intravenous injection was by Prinzmetal and associates. They used a relatively unshielded Geiger tube and Na. Despite relative insensitivity of Geiger tubes to hard gamma rays, they were able to detect (by in vivo analysis) two peaks of radioactivity representing the entry...
متن کاملCardiac output of men and dogs measured by in vivo analysis of iodinated (I 131) human serum albumin.
THE first published effort to record the intensity of radioactivity as a function of time over the heart following a single intravenous injection was by Prinzmetal and associates. They used a relatively unshielded Geiger tube and Na. Despite relative insensitivity of Geiger tubes to hard gamma rays, they were able to detect (by in vivo analysis) two peaks of radioactivity representing the entry...