منابع مشابه
A New Approach to Ventilation Measurements in Enclosure Fires
The application of Stereoscopic Particle Image Velocimetry (SPIV) is a new approach to quantifying the ventilation in enclosure fires. Stereoscopic PIV is a non-intrusive optical measurement technique which measures the displacement of tracer particles in a flow. The technique is completely independent of temperature and differential pressure measurements typically applied to quantify ventilati...
متن کاملThe Process of Human Behavior in Fires
Evacuation models, including engineering hand calculations and computational tools, are used to calculate the time it takes to evacuate a building, which can then be used in an engineering safety analysis. However, there is a lack of available data and theory on occupant behavior for use by evacuation models to estimate evacuation time results and their uncertainty. In lieu of data and theory, ...
متن کاملSpread and burning behavior of continuous spill fires
General rights Copyright for the publications made accessible via the Edinburgh Research Explorer is retained by the author(s) and / or other copyright owners and it is a condition of accessing these publications that users recognise and abide by the legal requirements associated with these rights. Take down policy The University of Edinburgh has made every reasonable effort to ensure that Edin...
متن کاملBEHAVIOR OF SOLUTIONS TO A FUZZY NONLINEAR DIFFERENCE EQUATION
In this paper, we study the existence, asymptotic behavior of the positive solutions of a fuzzy nonlinear difference equation$$ x_{n+1}=frac{Ax_n+x_{n-1}}{B+x_{n-1}}, n=0,1,cdots,$$ where $(x_n)$ is a sequence of positive fuzzy number, $A, B$ are positive fuzzy numbers and the initial conditions $x_{-1}, x_0$ are positive fuzzy numbers.
متن کاملNonlinear Responses and Optical Limiting Behavior of Ag Nanoparticle Suspension
In this study, the nonlinear optical properties and optical limiting performance of the silver nanoparticles (AgNPs) in distilled water are investigated. The nonlinear absorption coefficient of the colloid is measured by the Z-scan technique. The optical limiting behavior of the AgNP suspension is investigated under exposure to nanosecond laser pulses at 532 nm. The results show that nonlinear ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Architectural Institute of Japan
سال: 1983
ISSN: 0387-1185,2433-0027
DOI: 10.3130/aijsaxx.332.0_145