Non-Union Current Treatment Concept
نویسندگان
چکیده
منابع مشابه
Effect of Teriparatide (CinnoPar®) in Treatment of Non::union:: Bone Fractures
Background and purpose: Non::union:: of bone fracture is a clinical and treatment challenge. Satisfactory repair of orthopedic fractures is of great importance and systemic treatment is used to achieve this goal. This study aimed to investigate the effect of Teriparatide (CinnoPar®) on non::union:: fractures. Materials and methods: A quasi-experimental study was conducted in 17 patients with n...
متن کاملPAUWELS\' OSTEOTOMY FOR FEMORAL NECK NON-:union:
During a period of nine years (1982-1991), Pauwels' osteotomy was performed for 38 cases of femoral neck non-:::union:::. 32 led to consolidation with one osteotomy (84%) and 6 failed (3 needed revision (92%), one died and two were lost to follow-up). The length of follow-up was 2-11 years, the average time of non-:::union::: 12 months (ranging from 4 months to 13 years) and the mean patien...
متن کاملThe treatment of infected and uninfected non-union.
One hundred and sixteen patients with 129 ununited fractures were treated either by rigid internal fixation and bone grafting or, in 14 tibial non-unions, by posterolateral bone grafting. In 37 actively infected cases this was combined with sequestrectomy and appropriate antibiotics. The final success rate was 98.4%. Technical errors or inadequate immobilisation after operation in patients with...
متن کاملFemoral neck non-union treatment by valgus intertrochanteric osteotomy.
OBJECTIVE : The purpose of this study was to evaluate the performance of valgus intertrochanteric osteotomy in femoral neck non-union. METHODS : Forty-two patients with femoral neck fractures with non-union treated using Pauwels' intertrochanteric osteotomy were reviewed. Demographics, time elapsed between fracture and surgery, follow--up, osteosynthesis used, Garden's classification, limb sh...
متن کاملSuccessful treatment of sternal non-union by ultrasound.
We report a case of sternal non-union after open aortic valve replacement surgery in a 48-year-old man. The sternotomy was repaired using stainless steel wires and later, 'flexigrip' cables. He presented to us six months later complaining of persistent pain in the sternotomy site. CT-scan confirmed a sternal non-union. After consultation with the ultrasound device, and aortic valve manufacturer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Shafa Orthopedic Journal
سال: 2016
ISSN: 2345-296X,2383-4315
DOI: 10.17795/soj-4546