No-Transfer Winkler Method for Dissolved Oxygen with Conventional Equipment.
نویسندگان
چکیده
منابع مشابه
The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method
A modified technique for the Winkler determination of dissolved oxygen has been used at the Chesapeake Bay Institute for several years. The modifications result in increased simplicity and speed and reduction in the errors due to manipulation. The unusual features of the technique are the elimination of the volumetric transfer of the final iodine solution and the reagent concentrations. The sou...
متن کاملMeasurement of Dissolved Oxygen in Swamp Waters. Further Modification of the Winkler Method
INTRODUCTION There have been several modifications of the original Winkler method for the estimation of dissolved oxygen (Winkler, 1888) designed to overcome the sources of error due to the presence of oxidizing and reducing substances in natural waters and industrial wastes. In the course of work on tropical swamps we have been interested in the amount of oxygen in water which not only may con...
متن کاملAn Automated Precise Winkler Titration for Determining Dissolved Oxygen on Board Ship
An automated titration for the Winkler method is presented for measuring primary productivity in the ocean. The system is based on a microcomputercontrolled titration with potentiometric endpoint detection. By the use of 0.005-N sodium thiosulfate as a titrant and a program designed to shorten the time for measuring, the method achieves a precision of 0.04% coefficient of variation with a range...
متن کاملSpectrophotometric Winkler determination of dissolved oxygen: re-examination of critical factors and reliability
The spectrophotometric iodine measurement for oxygen determination by the Winkler method is reexamined for theoretical and operational aspects. It is shown that the selection of an isobestic point for measuring the mixture of iodine and tri-iodide in the solution enhances reliability. The wavelength value of 466 nm was selected after a spectrum study. Then, performances are assessed by mean of ...
متن کاملOptical Analyzer for Continuous Monitoring of Dissolved Oxygen in Aviation Fuel and Other Non-aqueous Media
A special sensitive element based on the novel composite material was created. The sensor has a linear calibration and is resistant to aliphatic hydrocarbons, in particular aviation fuel. A low cost and easy-to-implement method for calibrating the sensor was proposed. Temperature dependence of the oxygen mass transfer coefficient kL was measured for aviation fuel TS-1 (Russi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NIPPON SUISAN GAKKAISHI
سال: 1992
ISSN: 1349-998X,0021-5392
DOI: 10.2331/suisan.58.1887