New potentiometric sensors for methylphenidate detection based on host–guest interaction

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influences of Probe's Morphology for Metal Ion Detection Based on Light-Addressable Potentiometric Sensors

The sensing mechanism of binding Hg(2+) into thymine-thymine (T-T) mismatched base pairs was introduced into a light-addressable potentiometric sensor (LAPS) with anti-Hg(2+) aptamer as the sensing units. Three kinds of T-rich single-strand DNA (ssDNA) chains with different spacer lengths, from 0 to 12 -CH₂ groups, were designed to investigate surface charge and morphological effects on the LAP...

متن کامل

Modern Directions for Potentiometric Sensors.

This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the underlying membrane processes. The recent developments in lowering the detection ...

متن کامل

Potentiometric miniaturized pH sensors based on polypyrrole films

Submitted by Olivier Segut on Fri, 11/07/2014 16:35 Titre Potentiometric miniaturized pH sensors based on polypyrrole films Type de publication Article de revue Auteur Lakard, Boris [1], Segut, Olivier [2], Lakard, Sophie [3], Herlem, Guillaume [4], Gharbi, Tijani [5] Editeur Elsevier Type Article scientifique dans une revue à comité de lecture Année 2007 Langue Anglais Date Jan-03-2007 Numéro ...

متن کامل

Novel ibuprofen potentiometric membrane sensors based on tetraphenylporphyrinato indium(III).

Two novel potentiometric membrane sensors responsive to the ibuprofen drug have been developed. These incorporate poly(vinyl chloride) and polyurethane matrix membranes containing 5,10,15,20-tetraphenylporphrinato (TPP) indium(II) ionophore plasticized with dibutylsebacate. The sensors show a near-Nernstian response with anionic slopes of -53 and -55 mV decade(-1), over the concentration range ...

متن کامل

Carbon Nanotubes-Based Potentiometric Bio-Sensors for Determination of Urea

The possibility of using disposable plastic-carbon potentiometric sensors as enzyme biosensors was examined. Urease enzyme was immobilized on poly(vinyl chloride) based Hor NH4-selective membranes using cellulose acetate. This approach has resulted in a potentiometric response on changing the pH of the solution or NH4 ion content due to an enzymatic reaction that occurs between urease and urea....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMC Chemistry

سال: 2019

ISSN: 2661-801X

DOI: 10.1186/s13065-019-0634-3