New implant for drainage in glaucoma. Clinical trial.
نویسندگان
چکیده
منابع مشابه
New implant for drainage in glaucoma. Clinical trial.
(2) A thin acrylic plate is rigidly attached to this tube in such a way that the lumen of the tube opens onto the upper surface of the plate. This plate (8 mm. in diameter and approximately circular in outline) is curved to fit and firmly sutured to the sclera. When covered by a flap of conjunctiva and Tenon's capsule, the plate forms the floor of a blel) wvhich is in free communication with th...
متن کاملNew implant for drainage in glaucoma. Animal trial.
The implant described in this communication is the direct descendent of a long series of artificial drainage devices which began when Zorab (I9I2) inserted a silk thread through the limbus in order to drain aqueous into the subconjunctival space in cases of glaucoma (see also Mayou, I9I2). Among the more recently described devices are teflon drainage tubes in man (Richards, I955; Epstein, 1959;...
متن کاملClinical Experience with the M4 Ahmed Glaucoma Drainage Implant
Aim To evaluate the safety and efficacy of the M4 (porous polyethylene plate) Ahmed Glaucoma Valve (AGV) drainage implant in a multicenter retrospective study. Materials and methods A retrospective chart review of medical records of patients who had undergone the M4 Ahmed valve was performed from January 2013 to April 2015. The primary outcome measure was surgical failure defined as: Less tha...
متن کامل[Simultaneous pars plana vitrectomy and glaucoma drainage device implant].
PURPOSE To evaluate intraocular pressure (IOP) and visual acuity (VA) results after glaucoma drainage device (GDD) implantation combined with simultaneous pars plana vitrectomy (PPV). MATERIAL AND METHODS Retrospective review of 8 eyes (7 patients). The diagnosis was neovascular glaucoma (NVG) secondary to proliferative diabetic retinopathy in 4 eyes, in a which a double plate Molteno implant...
متن کاملNew Glaucoma surgery improving Anterior Aqueous Drainage
Introduction Anti-glaucoma medicines, laser surgery and incisional surgery all seek to lower the intraocular pressure (IOP). Incisional surgery is indicated when medical treatment and/or laser surgery have failed, are likely to fail or are not available or practical. The most standard surgical procedure is trabeculectomy (or some variation thereof e.g. ExPRESS shunt): aqueous is shunted from th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Ophthalmology
سال: 1969
ISSN: 0007-1161
DOI: 10.1136/bjo.53.9.606