New approach to 3D time-resolved angiography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved contrast-enhanced 3D MR angiography.

An MR angiographic technique, referred to as 3D TRICKS (3D time-resolved imaging of contrast kinetics) has been developed. This technique combines and extends to 3D imaging several previously published elements. These elements include an increased sampling rate for lower spatial frequencies, temporal interpolation of k-space views, and zero-filling in the slice-encoding dimension. When appropri...

متن کامل

Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Contrast-enhanced magnetic resonance angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3-4 mm spatial resolution with acquisition times in the 30-second range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution 3D time-resolved studies. The pu...

متن کامل

Application of Time-Resolved 3D Digital Subtraction Angiography to Plan Cerebral Arteriovenous Malformation Radiosurgery.

BACKGROUND AND PURPOSE Time-resolved 3D-DSA (4D-DSA) enables viewing vasculature from any desired angle and time frame. We investigated whether these advantages may facilitate treatment planning and the feasibility of using 4D-DSA as a single imaging technique in AVM/dural arteriovenous fistula radiosurgery. MATERIALS AND METHODS Twenty consecutive patients (8 dural arteriovenous fistulas and...

متن کامل

Very Low Dose Time-resolved MR Angiography

Introduction: Time resolved contrast-enhanced MR angiography has been increasingly used to evaluate the hemodynamic status of normal versus abnormal vasculatures. Fast imaging sequences, parallel imaging, and view-sharing techniques have been applied to provide the needed temporal and spatial resolution. The Gadolinium-based contrast agent is sometimes injected in double dose to enhance the ima...

متن کامل

Time-resolved angiography: Past, present, and future.

The introduction of digital subtraction angiography (DSA) in 1980 provided a method for real time 2D subtraction imaging. Later, 4D magnetic resonance (MR) angiography emerged beginning with techniques like Keyhole and time-resolved imaging of contrast kinetics (TRICKS) that provided frame rates of one every 5 seconds with limited spatial resolution. Undersampled radial acquisition was subseque...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2002

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.10151