Near-Infrared Intraoperative Chemiluminescence Imaging
نویسندگان
چکیده
منابع مشابه
Intraoperative near-infrared fluorescent imaging during robotic operations
The intraoperative identification of certain anatomical structures because they are small or visually occult may be challenging. The development of minimally invasive surgery brought additional difficulties to identify these structures due to the lack of complete tactile sensitivity. A number of different forms of intraoperative mapping have been tried. Recently, the near-infrared fluorescence ...
متن کاملIntraoperative Near - infrared Indocyanine Green Videoangiography
Fluorescence angiography was first used by ophthalmologists to measure retinal blood flow by using the fluorescent dye fluorescein. Feindel et al.1,2 were the first to apply the concept of fluorescence angiography to the intraoperative visualisation of cerebral vertebral arteries and cerebral microcirculation in patients undergoing neurosurgical procedures.3,4 With the use of indocyanine green ...
متن کاملMedical near-infrared imaging
The use of near-infrared light in functional medical imaging has gained increasing interest during recent years. Techniques using near-infrared light for imaging can be used to study, e.g., hemodynamic responses on the cortex. Brain activation measurements can be performed using, e.g., MEG or fMRI, which, however, require heavy instrumentation. In medical near-infrared imaging, the instrumentat...
متن کاملI. Near-infrared imaging
As a prerequisite for cosmological studies using adaptive optics techniques, we have begun to identify and characterize faint sources in the vicinity of bright stars at high Galactic latitudes. The initial phase of this work has been a program of Ks imaging conducted with SOFI at the ESO NTT. From observations of 42 southern fields evenly divided between the spring and autumn skies, we have ide...
متن کاملNear - Infrared Wide - Field Imaging
We have constructed a near-infrared imaging camera which is attached to the prime focus of 105cm Schmidt telescope at Kiso Observatory. The camera is equipped with a 10401040 PtSi CSD array developed by Mitsubishi Electric Co. The combination of Kiso Schmidt and the array gives a wide eld of view of 18:4 0 18:4 0 with a reasonable spatial resolution of 1:06"=pixel. The system performances of th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ChemMedChem
سال: 2016
ISSN: 1860-7179
DOI: 10.1002/cmdc.201600301