Multispectral UAS Data Accuracy for Different Radiometric Calibration Methods
نویسندگان
چکیده
منابع مشابه
Methods for Lwir Radiometric Calibration and Characterization
The utility of a thermal remote sensing system increases with its ability to retrieve surface temperature or radiance accurately. Several applications require absolute or relative accuracies far better than 1 C. To achieve these levels of accuracy routinely, scientists must perform laboratory and onboard calibration as well as in-flight vicarious characterization, incorporating a wellcalibrated...
متن کاملRadiometric Cross-Calibration of GF-4 in Multispectral Bands
The GaoFen-4 (GF-4), launched at the end of December 2015, is China’s first high-resolution geostationary optical satellite. A panchromatic and multispectral sensor (PMS) is onboard the GF-4 satellite. Unfortunately, the GF-4 has no onboard calibration assembly, so on-orbit radiometric calibration is required. Like the charge-coupled device (CCD) onboard HuanJing-1 (HJ) or the wide field of vie...
متن کاملRadiometric Calibration Methods from Image Sequences
Seon Joo Kim: Radiometric Calibration Methods from Image Sequences. (Under the direction of Marc Pollefeys.) In many computer vision systems, an image of a scene is assumed to directly reflect the scene radiance. However, this is not the case for most cameras as the radiometric response function which is a mapping from the scene radiance to the image brightness is nonlinear. In addition, the ex...
متن کاملRadiometric Calibration for AgCam
The student-built Agricultural Camera (AgCam) now onboard the International Space Station observes the Earth surface through two linescan cameras with Charge-Coupled Device (CCD) arrays sensitive to visible and near-infrared wavelengths, respectively. The electro-optical components of the AgCam were characterized using precision calibration equipment; a method for modeling and applying these me...
متن کاملRadiometric Calibration of Sar Image Data
Recent advances in calibration techniques have made calibrated SAR images, in which the data represents radar cross-section (0') or normalized radar cross-section (0'0), a reality. In this paper, some of these recent advances are discussed in the context of their impact on SAR sys'tem design, and in terms of the errors associated with each technique. The main sources of error in radiometric cal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Remote Sensing
سال: 2019
ISSN: 2072-4292
DOI: 10.3390/rs11161917