منابع مشابه
Internet remote control interface for a multipurpose robotic arm
This paper presents an Internet remote control interface for a MITSUBISHI PA10-6CE manipulator established for the purpose of the ROBOT museum exhibition during spring and summer 2004. The robotic manipulator is a part of the Intelligent Robotic Systems Laboratory at Heriot – Watt University, which has been established to work on dynamic and kinematic aspects of manipulator control in the prese...
متن کاملAn LPV Approach to Sensor Fault Diagnosis of Robotic Arm
One of the major challenges in robotic arms is to diagnosis sensor fault. To address this challenge, this paper presents an LPV approach. Initially, the dynamics of a two-link manipulator is modelled with a polytopic linear parameter varying structure and then by using a descriptor system approach and a robust design of a suitable unknown input observer by means of pole placement method along w...
متن کاملMind Controlled Robotic Arm
Electro Encephalo Gram based Brain-Computer Interface robotic arm can help as a powerful support for severely disabled people in their regular activities, especially to aid them to move their arm voluntarily. This paper proposes and implements a brain signal (mind) controlled robotic arm to yield different movements in robotic arm. The scheme uses a single electrode pair acquisition scheme, mic...
متن کاملRobotic Arm for Remote Surgery
Recent advances in telecommunications have enabled surgeons to operate remotely on patients with the use of robotics. The investigation and testing of remote surgery using a robotic arm is presented. The robotic arm is designed to have four degrees of freedom that track the surgeon’s x, y, z positions and the rotation angle of the forearm θ. The system comprises two main subsystems viz. the det...
متن کاملA robotic C-arm fluoroscope.
Fluoroscopic C-arms are common devices for acquiring images during surgery. Manual positioning is time consuming and requires considerable experience. Trained users must often take several images to find the best viewing direction. If a second image must be taken from the same position, e.g. for postoperative control, the C-arm must be moved to the exact same position. Without guidance, this is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal for Research in Applied Science and Engineering Technology
سال: 2020
ISSN: 2321-9653
DOI: 10.22214/ijraset.2020.6266