Multiple Acetabular Revisions in THA - Poor Outcome Despite Maximum Effort

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiple Acetabular Revisions in THA - Poor Outcome Despite Maximum Effort

A consecutive series of 52 acetabular revisions was evaluated retrospectively. Inclusion criteria for all patients were at least one former exchange of the acetabular component. Reconstruction was performed with reliable techniques and implants other than extensively porous coated device (e.g. tantalum). The mean follow up was 5.63 (0.01-14.05) years. Cumulative survival at 14.05 years with rem...

متن کامل

Predictors of poor outcome despite recanalization: a multiple regression analysis of the NASA registry.

BACKGROUND Mechanical thrombectomy with stent-retrievers results in higher recanalization rates compared with previous devices. Despite successful recanalization rates (Thrombolysis in Cerebral Infarction (TICI) score ≥2b) of 70-83%, good outcomes by 90-day modified Rankin Scale (mRS) score ≤2 are achieved in only 40-55% of patients. We evaluated predictors of poor outcomes (mRS >2) despite suc...

متن کامل

Measuring acetabular component version after THA: CT or plain radiograph?

BACKGROUND Although cross-table lateral radiographs are commonly used to measure acetabular component version after THA, recent studies suggest that CT-based measurement is more accurate. This has been attributed to variations in pelvic tilt, pelvic rotation, and component inclination. Furthermore, it has been suggested, based on limited data, that even with ideal positioning of the cross-table...

متن کامل

A retrospective cohort study of 207 acetabular revisions

© 2016 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0) DOI 10.1080/17453674.2016.1248315 Background and purpose — Porous tantalum cups have been introduced as an alternative to various r...

متن کامل

Short-term results of a custom triflange acetabular component for massive acetabular bone loss in revision THA.

Managing severe periacetabular bone loss during revision total hip arthroplasty (THA) is a challenging task. Multiple treatment options have been described. A custom triflanged acetabular component is a recent treatment option. The authors retrospectively reviewed 19 hips in 19 patients with massive periacetabular bone loss (Paprosky types 3A/3B and AAOS types III/IV) treated with custom trifla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Open Orthopaedics Journal

سال: 2012

ISSN: 1874-3250

DOI: 10.2174/1874325001206010488