MTR variations in normal adult brain structures using balanced steady-state free precession

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resting-State fMRI Using Passband Balanced Steady-State Free Precession

OBJECTIVE Resting-state functional MRI (rsfMRI) has been increasingly used for understanding brain functional architecture. To date, most rsfMRI studies have exploited blood oxygenation level-dependent (BOLD) contrast using gradient-echo (GE) echo planar imaging (EPI), which can suffer from image distortion and signal dropout due to magnetic susceptibility and inherent long echo time. In this s...

متن کامل

SNR using balanced steady-state free precession (b-SSFP)

A brief overview of the signal-to-noise ratio in MR imaging; including the sources of signal and noise and their respective parameters for optimization. In particular, the balanced SSFP sequence is presented as an example of a special type of gradient-echo (GE) sequence where the dephasing due to readout gradient is exactly zero. Thus b-SSFP yields a very high SNR, in some applications, by cont...

متن کامل

Imaging periodic currents using alternating balanced steady-state free precession.

Existing functional brain MR imaging methods detect neuronal activity only indirectly via a surrogate signal such as deoxyhemoglobin concentration in the vascular bed of cerebral parenchyma. It has been recently proposed that neuronal currents may be measurable directly using MRI (ncMRI). However, limited success has been reported in neuronal current detection studies that used standard gradien...

متن کامل

FMRI using balanced steady-state free precession (SSFP)

Steady-state free precession (SSFP) is a highly-efficient MRI pulse sequence that has been a fairly recent arrival in the functional MRI realm. Several methods for using balanced SSFP to detect the BOLD signal have been proposed to date and will be discussed in this review. After a brief introduction to the general properties of SSFP, this review describes the quite different approaches of tran...

متن کامل

Flow effects in balanced steady state free precession imaging.

An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady-state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various through-plane flow waveforms and rates were modeled numerically considering factors such as the excitation sli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Neuroradiology

سال: 2010

ISSN: 0028-3940,1432-1920

DOI: 10.1007/s00234-010-0714-5