MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MIRD dose estimate report No. 20: radiation absorbed-dose estimates for 111In- and 90Y-ibritumomab tiuxetan.

UNLABELLED Absorbed-dose calculations provide a scientific basis for evaluating the biologic effects associated with administered radiopharmaceuticals. In cancer therapy, radiation dosimetry supports treatment planning, dose-response analyses, predictions of therapy effectiveness, and completeness of patient medical records. In this study, we evaluated the organ radiation absorbed doses from in...

متن کامل

Accurate dose calibrator activity measurement of 90Y-ibritumomab tiuxetan.

UNLABELLED This investigation examined the accuracy of dose calibrator activity measurement of the beta-emitting radiopharmaceutical (90)Y-ibritumomab tiuxetan. METHODS Five different facilities independently measured (90)Y in a 10-mL syringe geometry with 30 dose calibrator models from 3 different manufacturers. The activities ranged from 81.4 MBq (2.2 mCi) to 1,406 MBq (38 mCi) over the vol...

متن کامل

Quantification of dose nonuniformities by voxel-based dosimetry in patients receiving 90Y-ibritumomab-tiuxetan.

UNLABELLED Abstract Objective: To assess the impact of nonuniform dose distribution within lesions and tumor-involved organs of patients receiving Zevalin(®), and to discuss possible implications of equivalent uniform biological effective doses (EU-BED) on treatment efficacy and toxicity. MATLAB™ -based software for voxel-based dosimetry was adopted for this purpose. METHODS Eleven lesions fr...

متن کامل

A phase 1/2 trial of high-dose yttrium-90-ibritumomab tiuxetan in combination with high-dose etoposide and cyclophosphamide followed by autologous stem cell transplantation in patients with poor-risk or relapsed non-Hodgkin lymphoma.

We conducted a phase 1/2 trial of high-dose 90Y-ibritumomab tiuxetan in combination with high-dose etoposide (VP-16) 40 to 60 mg/kg (day -4) and cyclophosphamide 100 mg/kg (day -2) followed by autologous stem cell transplantation (ASCT) in 31 patients with CD20+ non-Hodgkin lymphoma (NHL). Patients underwent dosimetry (day -21) with 5 mCi (185 MBq) 111In-ibritumomab tiuxetan following 250 mg/m2...

متن کامل

Determination of internal absorbed dose from radiation of 111In-Rituximab in body

Introduction: There are many ways to treat cancer and pain relief. One of the methods is radiopharmaceutical therapy. Indium 111-rituximab contains the radioisotope indium-111 and rituximab. The Indium-111, after decay, emits gamma rays with energies of 245 KeV and 171 KeV, and beta-radiation of 26 KeV. In this study, the absorbed dose of 111In-Rituximab in human body was calcu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Nuclear Medicine

سال: 2009

ISSN: 0161-5505,2159-662X

DOI: 10.2967/jnumed.108.057331