Minimum Temperature Difference Perceived for Undersampled Medical Thermal Imager
نویسندگان
چکیده
منابع مشابه
Thermal Model of Human Body Temperature Regulation Considering Individual Difference
This paper proposes the methodology to quantify the individual difference in temperature regulation of human body for transient simulation of body temperature. Experiments of transient thermal exposure were conducted for four subjects and the characteristics of individual difference in themoregulatory response were observed quantitatively. As the result, the differences in core temperature and ...
متن کاملLand Surface Temperature Retrieval from the Medium Resolution Spectral Imager (MERSI) Thermal Data
A single channel land surface temperature (LST) retrieval algorithm named Single Channel Water Vapor Dependent (SCWVD) method was presented for Medium Resolution Spectral Imager (MERSI) thermal infrared band aboard FengYun-3A (FY-3A) satellite. Water Vapor Content (WVC) is the only input parameter in the algorithm assuming the surface emissivity is known. NCEP reanalysis monthly mean datasets a...
متن کاملLand Surface Temperature Retrieval from the Medium Resolution Spectral Imager Thermal Data
A single channel land surface temperature (LST) retrieval algorithm named Single Channel Water Vapor Dependent (SCWVD) method was presented for Medium Resolution Spectral Imager (MERSI) thermal infrared band aboard FengYun-3A (FY-3A) satellite. Water Vapor Content (WVC) is the only input parameter in the algorithm assuming the surface emissivity is known. NCEP reanalysis monthly mean datasets w...
متن کاملThermal Modeling for Predication of Automobile Cabin Air Temperature
Thermal modeling of an automotive cabin was performed in this paper to predict the inside cabin air temperature. To implement this task, thermal and ventilation loads were estimated and the mass and energy balance conservation equations for dry air and water vapor with considering a new parameter (air circulation ratio) as well as the balance equations of internal components of a cabin were de...
متن کاملMulti-pixel Geiger mode imager for medical application
Nowadays, there are two types of sensors to detect the low luminous flux, PMT (Photomultiplier Tube) and Geiger-APD (Geiger Avalanche Photodiode). The domain of Geiger-APD has reached an advanced development in the last years. The basic idea of this structure consists in polarizing an APD in Geiger-mode by applying a voltage beyond its breakdown voltage. In this case of polarization, the APD is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Research Bulletin of the National Technical University of Ukraine "Kyiv Politechnic Institute"
سال: 2017
ISSN: 2519-8890,1810-0546
DOI: 10.20535/1810-0546.2017.5.100137