Minimally Invasive Plate Osteosynthesis Using a Locking Compression Plate for Diaphyseal Humeral Fractures
نویسندگان
چکیده
منابع مشابه
Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures.
PURPOSE To assess outcomes of minimally invasive plate osteosynthesis (MIPO) using a locking compression plate (LCP) for 42 humeral shaft fractures. METHODS. 28 men and 14 women aged 18 to 68 (mean, 34; median, 29) years underwent closed reduction and MIPO using a LCP for type 12-A (n=26) and type 12-B (n=16) humeral shaft fractures. Eight of the patients were aged ≥ 50 years. Patients were fol...
متن کاملMinimally invasive plate osteosynthesis using a locking compression plate for distal femoral fractures.
PURPOSE To evaluate treatment outcomes of minimally invasive plate osteosynthesis (MIPO) for distal femoral fractures in 31 patients. METHODS 22 male and 9 female consecutive patients aged 21 to 65 (mean, 42) years underwent minimally invasive plate osteosynthesis using a locking compression plate (LCP) for distal femoral fractures. The causes of injury were vehicular accidents (n=24), falls ...
متن کاملMinimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures
Background This study aims to compare the surgical outcomes of open reduction and internal fixation (ORIF) and minimally invasive plate osteosynthesis (MIPO) using a screw compression method in simple humeral shaft fractures. Methods This retrospective study was performed with 50 patients who had surgical interventions for the treatment of simple humeral shaft fractures and had follow-ups of ...
متن کاملMinimally Invasive Plate Osteosynthesis with Conventional Compression Plate for Diaphyseal Tibia Fracture.
The diaphyseal tibia fracture is best treated with intramedullary nail but in some cases where the nail is not applicable, plate fixation will be the next option of fixation. The extensile anterior approach is normally used for conventional compression plate fixation in tibia shaft fractures. The extensive surgical dissection may devitalizes the bony fragments and interfere with the fracture un...
متن کاملMinimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture
Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Orthopaedic Surgery
سال: 2012
ISSN: 2309-4990,2309-4990
DOI: 10.1177/230949901202000305