Minimally Invasive Off-Pump Technique for Temporary Left Ventricular Support
نویسندگان
چکیده
منابع مشابه
Transapical transcatheter device closure of relapse left ventricular diverticulum: a novel minimally invasive technique for reoperation
We describe a novel minimally invasive technique, transapical transcatheter device closure of relapse left ventricular diverticulum (LVD) under transesophageal echocardiography (TEE) guidance. The patient previously underwent LVD primary repair and mitral valvular replacement. The anatomical characteristics of the relapse LVD and its adjacent structures are detailedly delineated by echocardiogr...
متن کاملEmergency HeartWare Ventricular Assist Device (HVAD) exchange due to pump thrombosis using minimally invasive technique
Left ventricular assist device (LVAD) thrombosis remains a dreadful complication of mechanical circulatory support, with an incidence of 8-12% depending on the pump type and patient's comorbidities. Fibrinolysis may be considered early in pump thrombosis, but when contraindicated a pump exchange remains the only alternative. This short report documents an emergency LVAD exchange in a 55-year-ol...
متن کاملA dual therapy of off-pump temporary left ventricular extracorporeal device and amniotic stem cell for cardiogenic shock
BACKGROUND Temporary mechanical circulatory support device without sternotomy has been highly advocated for severe cardiogenic shock patient but little is known when coupled with amniotic stem cell therapy. CASE PRESENTATION This case reports the first dual therapy of temporary left ventricular extracorporeal device CentriMag with distal banding technique and human amniotic stem cell injectio...
متن کاملEpicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads
BACKGROUND We retrospectively assessed two types of sutureless screw-in left ventricular (LV) leads (steroid eluting vs. non-steroid eluting) in cardiac resynchronization therapy (CRT) implantation with regards to their electrical performance. METHODS Between March 2008 and May 2014 an epicardial LV lead was implanted in 32 patients after failed transvenous LV lead placement using a left-side...
متن کاملMinimally invasive off pump CABG technique using "LIMA to LAD" first in staged hybrid approach for complex Coronary artery disease
Method Between December 2012 and 2014 total 28 patients were taken up for Surgery using off pump MIDCAB and MICS CABG technique. LIMA was harvested in all cases using harmonic scalpel and target LAD grafting was done using polypropylene 7-0 or 8 0 depending on luminal size and quality of LIMA. All patients were evaluated with preoperative risk stratification and standard work up protocol includ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ASAIO Journal
سال: 2021
ISSN: 1058-2916
DOI: 10.1097/mat.0000000000001404