Million frames per second infrared imaging system
نویسندگان
چکیده
منابع مشابه
Million frames per second infrared imaging system
An infrared imaging system has been developed for measuring the temperature increase during the dynamic deformation of materials. The system consists of an 838 HgCdTe focal plane array, each with its own preamplifier. Outputs from the 64 detector/preamplifiers are digitized using a row-parallel scheme. In this approach, all 64 signals are simultaneously acquired and held using a bank of track a...
متن کاملBrandaris 128: A digital 25 million frames per second camera with 128 highly sensitive frames
A high-speed camera that combines a customized rotating mirror camera frame with charge coupled device ~CCD! image detectors and is practically fully operated by computer control was constructed. High sensitivity CCDs are used so that image intensifiers, which would degrade image quality, are not necessary. Customized electronics and instruments were used to improve the flexibility and control ...
متن کاملHolographic video at 40 frames per second for 4-million object points.
We propose a fast method for generating digital Fresnel holograms based on an interpolated wavefront-recording plane (IWRP) approach. Our method can be divided into two stages. First, a small, virtual IWRP is derived in a computational-free manner. Second, the IWRP is expanded into a Fresnel hologram with a pair of fast Fourier transform processes, which are realized with the graphic processing...
متن کاملHigh frame rate photoacoustic imaging at 7000 frames per second using clinical ultrasound system.
Photoacoustic tomography, a hybrid imaging modality combining optical and ultrasound imaging, is gaining attention in the field of medical imaging. Typically, a Q-switched Nd:YAG laser is used to excite the tissue and generate photoacoustic signals. But, such photoacoustic imaging systems are difficult to translate into clinical applications owing to their high cost, bulky size often requiring ...
متن کاملReal-time volumetric lipid imaging in vivo by intravascular photoacoustics at 20 frames per second.
Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets in swine coronary arteries in vivo, at a clinically useful frame rate of 20 s-1. We confirmed image contrast for athero...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2000
ISSN: 0034-6748
DOI: 10.1063/1.1310350