simulation and design of electronic processing circuit for restaurants e-procurement system

the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...

15 صفحه اول

Microwave-Assisted Tissue Preparation for Rapid Fixation, Decalcification, Antigen Retrieval, Cryosectioning, and Immunostaining

Microwave irradiation of tissue during fixation and subsequent histochemical staining procedures significantly reduces the time required for incubation in fixation and staining solutions. Minimizing the incubation time in fixative reduces disruption of tissue morphology, and reducing the incubation time in staining solution or antibody solution decreases nonspecific labeling. Reduction of incub...

متن کامل

Rapid microwave-stimulated fixation of entire prostatectomy specimens. Biomed-II MPC Study Group.

Conventional fixation of large solid surgical specimens is a slow process. Consequently, autolytic damage to tissues may occur if the fixative does not reach the central part of the specimen in time. However, as there is also a time relationship between formalin fixation and antigen masking, fixation for too long can also be detrimental. In seeking the optimum balance for fixation, microwave ir...

متن کامل

Microwave-stimulated fixation for electron microscopy using a domestic microwave oven.

We investigated microwave-stimulated fixation of tissues for transmission electron microscopy using a domestic microwave oven operating at a frequency of 2.45 GHz with an output power of 500W. Microwave-stimulated fixation, in 4% glutaraldehyde, of fresh rat kidney, liver, heart and brain tissues was compared to conventional fixation. Human renal biopsies were similarly studied. Electron micros...

متن کامل