Micro-CT evaluation of rotary and reciprocating glide path and shaping systems outcomes in maxillary molar curved canals
نویسندگان
چکیده
منابع مشابه
Shaping ability of reciprocating single-file and full-sequence rotary instrumentation systems in simulated curved canals
OBJECTIVE The purpose of this study was to evaluate the shaping ability of three nickel-titanium systems in simulated curved canals. MATERIALS AND METHODS Sixty simulated canals were prepared to apical size 25 with Reciproc, S5, and twisted file (TF) instruments. Standardized pre and postoperative images were taken using a digital camera, were superimposed and aberrations were recorded. Mater...
متن کاملeffectiveness of hedstroum files and rotary k3 instruments in removal of obturation materials during retreatment in curved canals
چکیده ندارد.
15 صفحه اولComparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals
Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...
متن کاملin vitro comparison of apical debris extrusion using rotary and reciprocating systems in severely curved root canals
introduction: the aim of this in vitro study was to compare the amount of apically extruded debris after root canal preparation using rotary and reciprocating systems in severely curved root canals. methods and materials: thirty six extracted human mandibular first molars with 25-35 ° curvature in their mesiobuccal (mb) canal (according to schneider’s method) were cleaned and shaped with protap...
متن کاملShaping ability of Mtwo and Twisted File rotary systems in curved root canals
Objective: To compare the straightening of root canal curvature, the apical transportation, the loss of working length and the working time using two rotary systems. Study design: Sixty buccal root canals with angles of curvature between 30 to 99o were instrumented with Mtwo and Twisted File rotary instruments. A series of preand post-operative radiographs were superimposed to determine the str...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Odontology
سال: 2021
ISSN: 1618-1247,1618-1255
DOI: 10.1007/s10266-021-00631-2