Micro-computed tomography study on bread dehydration and structural changes during ambient storage
نویسندگان
چکیده
This study investigated the structural changes in bread during ambient storage. The were studied using X-ray micro-computed tomography. Fresh had a porosity of 53.7 ± 1.6% and high pore connection value, suggesting that most pores are extensively interconnected. Moreover, fresh cell walls with an average thickness about 0.2 mm wide size distribution. During storage, underwent substantial water-loss, leading to volume shrinkage microstructural alterations. Significant increases total number small as well significant decrease wall observed over 14 storage days. Grayscale intensity obtained from images provided additional insights into network density, which is expected be correlated water distribution starch recrystallization staling.
منابع مشابه
X-ray micro-computed tomography
Micro-computed tomography (μCT) has been successfully used to study the cardiovascular system of mouse embryos in situ. With the use of barium as a suitablecontrast agent, blood vessels have beenimaged and analysed quantitatively such asblood volume and vessel sizes on embryosof ages 14.5 to 16.5 days old. The advantageof using this imaging modality is that it hasprovide...
متن کاملMeasurement of Structural Changes to a Food Material during Dehydration
Rates of dehydration/rehydration are important quality parameters for dried products. Theoretically, if there are no adverse effects on the integrity of the tissue structure, it should absorb water to the same moisture content of the initial product before drying.The purpose of this work is to semiautomate the process of detection of cell structure boundaries as a food is dehydrated and rehydra...
متن کاملComputed Tomography Structural Lung Changes in Discordant Airflow Limitation
BACKGROUND There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to classification of airflow limitation (FEV1/FVC <70% and/or < the lower limit of normal (LLN)) in (he...
متن کاملMicro computed tomography for vascular exploration
Vascular exploration of small animals requires imaging hardware with a very high spatial resolution, capable of differentiating large as well as small vessels, in both in vivo and ex vivo studies. Micro Computed Tomography (micro-CT) has emerged in recent years as the preferred modality for this purpose, providing high resolution 3D volumetric data suitable for analysis, quantification, validat...
متن کاملHemodynamic changes by flow diverters in rabbit aneurysm models: a computational fluid dynamic study based on micro-computed tomography reconstruction.
BACKGROUND AND PURPOSE The effect of flow diverter (FD) on hemodynamic changes observed in aneurysms is inevitably affected by the actual structural configuration of deployed FD. We studied the resultant hemodynamic changes after implantation of FDs using computational fluid dynamic simulations based on micro-computed tomography reconstructions in rabbit aneurysm model. METHODS The FDs by mic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Food Engineering
سال: 2021
ISSN: ['1873-5770', '0260-8774']
DOI: https://doi.org/10.1016/j.jfoodeng.2020.110462