Measurement of backscatter factor for kilovoltage x-ray beam using ionization chamber and Gafchromic XR-QA2 film
نویسندگان
چکیده
منابع مشابه
Gafchromic XR‐QA2 film as a complementary dosimeter for hand‐monitoring in CTF‐guided biopsies
Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the bas...
متن کاملMeasurement of high energy x-ray beam penumbra with Gafchromic EBT radiochromic film.
High energy x-ray beam penumbra are measured using Gafchromic EBT film. Gafchromic EBT, due to its limited energy dependence and high spatial resolution provide a high level of accuracy for dose assessment in penumbral regions. The spatial resolution of film detector systems is normally limited by the scanning resolution of the densitometer. Penumbral widths (80%/20%) measured at Dmax were foun...
متن کاملIonization Chamber Detector for X-ray with Beam Position Monitoring
Ionization Chambers have been commonly used at beamlines in many synchrotron radiation facilities. Typical ADC ion chambers are pictured in Figure 1. The chambers generate a current proportional to the incident X-ray beam intensity. The ionization chamber allows users to determine the change in beam position in a single axis by comparing two signals that are created as the beam passes through t...
متن کاملTime Response of a Gridded X-ray Beam Ionization Chamber*
Recently, Quick-Scanning Extended X-ray Absorption Fine Structure Spectroscopy (QEXAFS) has become an important tool for in-situ characterization of materials and measurement of associated electronic structure for where samples have a short life due to X-ray damage. In this case, the time response of the ionization chamber affects the measurement resolution and therefore overall performance of ...
متن کاملAdvances in kilovoltage x-ray beam dosimetry.
This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage...