Measurement of atom resolvability in cryo-EM maps with Q-scores
نویسندگان
چکیده
منابع مشابه
Bayesian Modeling of Biomolecular Assemblies with Cryo-EM Maps
A growing array of experimental techniques allows us to characterize the three-dimensional structure of large biological assemblies at increasingly higher resolution. In addition to X-ray crystallography and nuclear magnetic resonance in solution, new structure determination methods such cryo-electron microscopy (cryo-EM), crosslinking/mass spectrometry and solid-state NMR have emerged. Often i...
متن کاملModel-based local density sharpening of cryo-EM maps
Atomic models based on high-resolution density maps are the ultimate result of the cryo-EM structure determination process. Here, we introduce a general procedure for local sharpening of cryo-EM density maps based on prior knowledge of an atomic reference structure. The procedure optimizes contrast of cryo-EM densities by amplitude scaling against the radially averaged local falloff estimated f...
متن کاملQuantifying the local resolution of cryo-EM density maps
NATURE METHODS | VOL.11 NO.1 | JANUARY 2014 | 63 critical because local resolution tests are repeated at many points in the volume. Additionally, there is data dependency between neighboring points that windowed FSC does not account for. We propose a mathematical theory and an efficient algorithm for measuring local resolution that address all of the above limitations. The theory (Online Method...
متن کاملATTRACT-EM: A New Method for the Computational Assembly of Large Molecular Machines Using Cryo-EM Maps
Many of the most important functions in the cell are carried out by proteins organized in large molecular machines. Cryo-electron microscopy (cryo-EM) is increasingly being used to obtain low resolution density maps of these large assemblies. A new method, ATTRACT-EM, for the computational assembly of molecular assemblies from their components has been developed. Based on concepts from the prot...
متن کاملAll-atom structural investigation of kinesin-microtubule complex constrained by high-quality cryo-electron-microscopy maps.
In this study, we have performed a comprehensive structural investigation of three major biochemical states of a kinesin complexed with microtubule under the constraint of high-quality cryo-electron-microscopy (EM) maps. In addition to the ADP and ATP state which were captured by X-ray crystallography, we have also modeled the nucleotide-free or APO state for which no crystal structure is avail...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nature Methods
سال: 2020
ISSN: 1548-7091,1548-7105
DOI: 10.1038/s41592-020-0731-1