Mass-removal and mass-flux-reduction behavior for idealized source zones with hydraulically poorly-accessible immiscible liquid
نویسندگان
چکیده
منابع مشابه
Impact of enhanced-flushing reagents and organic-liquid distribution on mass removal and mass-discharge reduction.
A series of column and flow-cell experiments was conducted to investigate the impact of non-uniform organic-liquid distribution on the relationship between reductions in contaminant mass discharge and reductions in source zone mass under conditions of enhanced-solubilization flushing. Trichloroethene was used as the model organic liquid, and SDS (sodium dodecyl sulfate) and ethanol were used as...
متن کاملCoupling Aggressive Mass Removal with Microbial Reductive Dechlorination for Remediation of DNAPL Source Zones: A Review and Assessment
The infiltration of dense non-aqueous-phase liquids (DNAPLs) into the saturated subsurface typically produces a highly contaminated zone that serves as a long-term source of dissolved-phase groundwater contamination. Applications of aggressive physical-chemical technologies to such source zones may remove > 90% of the contaminant mass under favorable conditions. The remaining contaminant mass, ...
متن کاملMass flux characteristics in solid 4He for T>100 mK: evidence for bosonic Luttinger-liquid behavior.
At a pressure of ~25.7 bar, the flux F carried by solid (4)He for T>100 mK depends on the net chemical potential difference between two reservoirs in series with the solid, Δμ, and obeys F~(Δμ)(b), where b≈0.3 is independent of temperature. At fixed Δμ the temperature dependence of the flux F can be adequately represented by F~-ln(T/τ), τ≈0.6 K, for 0.1≤T≤0.5 K. A single function F=F(0)(Δμ)(b)l...
متن کاملMass Participation Factor in Defining Non-classical Range of Behavior for Mass Isolated Systems
The new techniques in seismic design of structures are usually attributed to high damping ratios. In such systems, the assumption of classical (i.e. proportional) damping is not valid and in most cases they should be considered as Non-classical systems. Since the analytical tools for studying the behavior of such structures are not easily available, the present work attempts to find the limits,...
متن کاملMass Participation Factor in Defining Non-classical Range of Behavior for Mass Isolated Systems
The new techniques in seismic design of structures are usually attributed to high damping ratios. In such systems, the assumption of classical (i.e. proportional) damping is not valid and in most cases they should be considered as Non-classical systems. Since the analytical tools for studying the behavior of such structures are not easily available, the present work attempts to find the limits,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemosphere
سال: 2008
ISSN: 0045-6535
DOI: 10.1016/j.chemosphere.2007.11.064