Manual and Semi-Automated Procedures for Measurement of Triglycerides in Serum

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems

This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...

متن کامل

Improved manual spectrophotometric procedure for determination of serum triglycerides.

We have modified the procedure of Levy [Ann. C/in. Lab. Sd. 6, 474 (1972)] for determination of serum triglycerides. The changes consist of using heptane in place of normane; using concentrated aqueous potassium hydroxide instead of sodium methylate as the saponifying reagent; and a somewhat higher saponification, oxidation, and condensation temperature. Consequently, the yellow dehydrolutidine...

متن کامل

Simplified manual micromethod for determination of serum triglycerides.

This rapid, simplified assay for serum triglycerides is based on the use of a more effective solvent extraction procedure, ethoxide transesterification, and color development with acetylacetone. No phospholipid adsorption step is necessary. The procedure requires less than 0.2 ml of serum, no expensive or elaborate apparatus, and 5 to 10 values can be obtained per hour, with better precision th...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

Manual and automated methods for urea nitrogen measurement in whole serum.

A simple method is described for directly determining serum urea nitrogen, wtihout deproteinization. The urea in 20 Ml of serum or plasma is reacted with diacetylmonoxime in the presence of thiosemicarbazide and cadmium ion under acid conditions. The absorbance of the resulting rose-purple solution is measured at 540 nm. Results agreed excellently with those obtained by a reference method that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 1975

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/21.11.1575