Magneto-Optical Traps for Cold Atomic Gravimetry: Research Status and Development Trends

نویسندگان

چکیده

The cold atomic gravimeter (CAG) has the advantage of high measurement accuracy and does not need to be calibrated on a regular basis. To achieve atom interference, it is first necessary cool trap atoms by magneto-optical (MOT). However, there are many types MOTs, their trapping cooling results directly affect thus, CAG. MOTs should designed or selected correctly for different application needs. This paper reviews research history analyzes structure principles. current status applications highlighted. Their advantages disadvantages summarized, perspectives development gravimetry presented.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atomic density and temperature distributions in magneto-optical traps

A theoretical investigation into density, pressure, and temperature distributions in magneto-optical traps is presented. After a brief overview of the forces that arise from reradiation and absorption, a condition that the absorptive force be conservative is used to show that, if the temperature is uniform throughout the trap, any density solutions to the force equations will not be physical. F...

متن کامل

Controlling Magneto-Optical Rotation via Atomic Coherences

An isotropic medium, having magnetic sublevels, when subjected to a magnetic field or an electromagnetic field can induce anisotropy in the medium; and as a result the plane of polarization of the probe field can rotate. Therefore the rotation due to the magnetic field alone, can be controlled efficiently with use of a coherent field. We show, using a control field, significant enhancement of t...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in Rb has been constructed and tested towards a goal of airborne detection of 87 magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidi...

متن کامل

Self-driven nonlinear dynamics in magneto-optical traps

We present a theoretical model describing recently observed collective effects in large magnetooptically trapped atomic ensembles. Based on a kinetic description we develop an efficient test particle method, which in addition to the single atom light pressure accounts for other relevant effects such as laser attenuation and forces due to multiply scattered light with position dependent absorpti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2023

ISSN: ['2076-3417']