Low-dose total body irradiation facilitates antitumoral Th1 immune responses
نویسندگان
چکیده
منابع مشابه
Waldenstrom’s Macroglobulinemia treated with fractionated low-dose total body irradiation
Case Report: A 78-year-old male with relapsed Waldenstrom’s macroglobulinemia following therapy with chlorambucil underwent a five-week course of TBI. The total dose delivered was 1.5 Gy, given as 0.15 Gy twice weekly for ten sessions. During the course of therapy his CD4 cells increased from 637 (cells/mm3) to 808 partly through treatment and then declined to 654 at the completion of therapy. ...
متن کامل[Antitumor effects by low dose total body irradiation].
Total-body irradiation (TBI) with 0.02-0.25 Gy has been reported to have antitumor effects. In mice, low-dose TBI induces tumor growth delay, antimetastatic effects, suppressive effects on the incidence of spontaneous thymiclymphoma, sensitization of tumor to ionizing radiation, and decrease in TD50 value. In artificial metastasis, 0.20 Gy TBI suppressed lung metastasis when it was conducted be...
متن کاملDiode calibration for dose determination in total body irradiation
Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...
متن کاملdiode calibration for dose determination in total body irradiation
background: total body irradiation (tbi) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under tbi treatment. diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. the aim of this study was to describe the measurements made to calibrate diod...
متن کاملTotal body irradiation dose optimization based on radiological depth
We have previously demonstrated the use of Eclipse fluence optimization to define aperture sizes for a novel aperture modulated translating bed total body irradiation (TBI) technique. The purposes of the present study were to identify, characterize, and correct for sources of error inherent in our previous fluence optimization technique, and to develop a clinically viable fluence optimization m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Theranostics
سال: 2021
ISSN: 1838-7640
DOI: 10.7150/thno.61459