Linearity of charge measurement in laser filaments

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of the Charge Radii of Li using Laser Spectroscopy

The radioactive isotopes of lithium have been the subject of numerous investigations, particularly after the discovery of the exotic Halo nucleus Li in 1985 [1]. Matter radii, excited states and electromagnetic moments have been determined. But the charge distribution inside the nuclei and how it is affected by the increasing number of neutrons is still an open question. Charge radii from cross...

متن کامل

Direct measurement of the electron density of extended femtosecond laser pulse-induced filaments.

We present direct time- and space-resolved measurements of the electron density of femtosecond laser pulse-induced plasma filaments. The dominant nonlinearity responsible for extended atmospheric filaments is shown to be field-induced rotation of air molecules.

متن کامل

Mid-infrared laser filaments in the atmosphere

Filamentation of ultrashort laser pulses in the atmosphere offers unique opportunities for long-range transmission of high-power laser radiation and standoff detection. With the critical power of self-focusing scaling as the laser wavelength squared, the quest for longer-wavelength drivers, which would radically increase the peak power and, hence, the laser energy in a single filament, has been...

متن کامل

Measurement of Detector Linearity and Effective Pathlength in Capillary Electrophoresis

www.lcgceurope.com Introduction The quality of photometric detection in capillary electrophoresis (CE) can be characterized by detector sensitivity and linearity. From the Beer-Lambert law it follows that the detector sensitivity is directly proportional to the detection pathlength. However, this might not be easy to estimate with cells with geometries that result in a range of possible pathlen...

متن کامل

Measurement of intermodulation distortion in high-linearity photodiodes.

Accurately characterizing third order intermodulation distortion (IMD3) in high-linearity photodiodes is challenging. Two measurement techniques are evaluated-a standard two-tone measurement and a more complicated three-tone measurement technique to measure IMD3. A model of the measurement system is developed and used to analyze the limitations of the two techniques in determining the distortio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2017

ISSN: 1094-4087

DOI: 10.1364/oe.25.016517