Lightning Impulse Current Tests on some Electroconductive Fabrics

نویسندگان

چکیده

On the search of lightweight lightning protection materials that can be used as part systems, we investigate some types electroconductive fabrics by applying several impulse currents in laboratory. Samples four commercially available textiles were analyzed, two rip-stop, a plain-weave, nonwoven, and additionally carbon-impregnated polymeric film. Under laboratory conditions, each sample was subjected to lengthwise subsequent lightning-like 8/20 us standard waveform, recording both voltage current signals. Optical scanning electron microscope observations performed after tests, revealing patterns or morphological changes on fabric surface. Despite these changes, investigated conductive withstand applied. Results suggest could personal mobile shelters, protect human beings against earth potential rise caused close discharge.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lightning Impulse Ageing of Hdpe

This work is concerned with the hypothesis that lightning impulses can lead to accelerated ageing of extruded polymeric cables. The behaviour of an insulation material when suffering lightning impulses is different from that for DC or power frequency over-voltages. Shaped HDPE material samples have been manufactured using a mould tool. The samples then may be electrically aged using one of the ...

متن کامل

Lightning Impulse Ageing of Hv Cable Insulation

Lightning impulses can lead to accelerated ageing of extruded cables. Electrical behaviour of a dielectric material when experiencing a lightning impulse is different to that for DC or power frequency applied voltages. Pre-designed shaped HDPE material samples have been manufactured using a mould tool. The samples then have been electrically aged using an impulse generator. A real-time software...

متن کامل

Lightning morphology and impulse charge moment change of high peak current negative strokes

[1] We have analyzed very high frequency lightning mapping observations and remote magnetic field measurements to investigate connections between lightning morphology and impulse charge moment change (iCMC) of negative cloud-to-ground (CG) strokes with high estimated peak currents. Four lightning morphologies are identified for a total of 2126 strokes within optimum detection range of the North...

متن کامل

On Some Impulse Control Problems with Constraint

The impulse control of a Markov–Feller process is considered when the impulses are allowed only when a signal arrives. This is referred to as an impulse control problem with constraint. A detailed setting is described, a characterization of the optimal cost is obtained using previous results of the authors on optimal stopping problems with constraint, and an optimal impulse control is identified.

متن کامل

Characterisation at Low Voltage of Two Reference Lightning Impulse Dividers

An effort is pursued by several European National Measurement Institutes to lower the uncertainties in calibration of UHV measuring systems for lighting impulse. To this end, several reference dividers are investigated as regards their accuracy both for amplitude and for time parameters. At SP RISE Research Institutes of Sweden, a 500 kV resistive reference divider has been in use since 2000. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of applied research and technology

سال: 2023

ISSN: ['2448-6736']

DOI: https://doi.org/10.22201/icat.24486736e.2023.21.2.1605