Laser diffraction microscopy
نویسندگان
چکیده
منابع مشابه
Spectroscopic diffraction phase microscopy.
We present spectroscopic diffraction phase microscopy (sDPM) as a method capable of measuring quantitative phase images at multiple wavelengths. sDPM uses a spatial light modulator at the Fourier plane of a lens to select desired wavelengths from the white light illumination of a grating. The quantitative phase information at different wavelengths allows us to decouple the refractive index and ...
متن کاملDiffraction phase and fluorescence microscopy.
We have developed diffraction phase and fluorescence (DPF) microscopy as a new technique for simultaneous quantitative phase imaging and epi-fluorescence investigation of live cells. The DPF instrument consists of an interference microscope, which is incorporated into a conventional inverted fluorescence microscope. The quantitative phase images are characterized by sub-nanometer optical path-l...
متن کاملWhite Light Diffraction Phase Microscopy
Quantitative phase imaging (QPI) techniques are very advantageous compared to the qualitative phase imaging techniques like bright field microscopy, phase contrast microscopy, differential interference contrast microscopy due to measurement of phase information quantitatively. In QPI techniques, there is no need of exogenous contrast agents to stain or tag the specimen. White light diffraction ...
متن کاملHigh-resolution optical diffraction microscopy.
In an optical diffraction microscopy experiment, one measures the phase and amplitude of the field diffracted by the sample and uses an inversion algorithm to reconstruct its map of permittivity. We show that with an iterative procedure accounting for multiple scattering, it is possible to visualize details smaller than lambda/4 with relatively few illumination and observation angles. The roles...
متن کاملSub-diffraction resolution pump-probe microscopy with shot-noise limited sensitivity using laser diodes.
We demonstrate the use of intensity-modulated laser diodes to implement pump-probe microscopy and achieved sub-diffraction resolution imaging with shot-noise limited sensitivity with a scheme of balanced detection. This technique has several applications for various types of induced transmission change, including excited-state absorption, ground state absorption bleaching and stimulated emissio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Reports on Progress in Physics
سال: 2009
ISSN: 0034-4885,1361-6633
DOI: 10.1088/0034-4885/72/7/076601