Jategaonkar’s Triple-Jerk Technique: A Safety Augmenting Method for Laparoscopic Suprapubic Trocar Insertion
نویسندگان
چکیده
منابع مشابه
High-Pressure Trocar Insertion Technique
BACKGROUND The majority of laparoscopic complications occur at the time of Veress needle and trocar insertion. Although not very frequent, they increase the morbidity and mortality of both diagnostic and operative laparoscopic procedures. Alternative techniques of trocar insertion have been described but have not completely eliminated the risk of injury. TECHNIQUE After Veress needle insertio...
متن کاملSuprapubic Laparoscopic Cholecystectomy: Technique and Preliminary Results
BACKGROUND The minimally invasive abdominal surgery has evolved to reduce portals, culminating with a single incision and natural orifice operation. However, these methods are still expensive, difficult to implement and with questionable aesthetic results. AIM To present the standardization and preliminary results of a technique for performing laparoscopic suprapubic access by the principle w...
متن کاملDirect Trocar Insertion Technique: an Alternative for Creation of Pneumoperitoneum
OBJECTIVES The direct trocar insertion technique (DTI) for the creation of pneumoperitoneum has been described as an alternative to open and Veress needle (VN) techniques. This study assesses the safety and feasibility of direct trocar insertion without a pre-existing pneumoperitoneum in patients undergoing elective laparoscopic procedures. METHODS From November 2001 to February 2006, we retr...
متن کاملMarionette method for transumbilical single-incision, two-trocar laparoscopic cholecystectomy: a new, simple technique.
BACKGROUND/AIMS Single-incision laparoscopic cholecystectomy (SILC) has recently become a topic of interest among types of minimally invasive surgery. METHODOLOGY We developed a novel "marionette method"technique for performing SILC. Two 5 mm trocars were placed through a 1.5 cm transumbilical incision. In addition, a nylon suture with a laparoscopic sliding knot was used to tighten the fundu...
متن کاملReduced-Force Closed Trocar Entry Technique: Analysis of Trocar Insertion Force Using a Mechanical Force Gauge
BACKGROUND AND OBJECTIVES Trocar insertion injury has a high morbidity, mortality, and cost. The purpose of this study was to compare standard trocar entry with our reduced-force closed trocar entry technique by measuring trocar insertion force using a mechanical force gauge. METHODS In the operating room, the force gauge was inserted into a sterile glove and connected to the proximal portion...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
سال: 2018
ISSN: 2249-782X
DOI: 10.7860/jcdr/2018/36038.11726