INVESTIGATION FOR PROPOSING EFFECTIVE QUALITY CONTROLLING TECHNOLOGY SECURING CONCRETE COVER THICKNESS IN REINFORCED CONCRETE CONSTRUCTION PROCESS
نویسندگان
چکیده
منابع مشابه
Cracking of Concrete Cover in Frp Reinforced Concrete Elements under Thermal Loads
Synopsis: The effects of thermal loads on the structural performance of FRP reinforced concrete elements are analyzed in this paper. The difference in transverse coefficient of thermal expansion (CTE) between FRP and concrete causes the presence of tensile stresses within the concrete and, eventually, the formation of cracks when the temperature increases. As part of an inter-university experim...
متن کاملObtaining Effective Half-Cell Potential Measurements in Reinforced Concrete Structures
Corrosion of steel reinforcement is a major factor in the deterioration of highway and bridge infrastructure. A survey of the condition of a reinforced concrete structure is the first step towards its rehabilitation. A rapid, cost-effective and non-destructive condition survey offers key information on the evaluation of corrosion, and aids in the quality assurance of concrete repair and rehabil...
متن کاملGlass Fibre Reinforced Concrete
Glass Fibre Reinforced Concrete is recent introduction in the field of concrete technology. The present day world is witnessing the construction of very challenging and difficult Civil Engineering Structures. Concrete being the most important and widely used material is called upon to possess very high strength and sufficient workability properties. Concrete the most widely used consrtuction ma...
متن کاملExperimental Investigation on Mechanical Properties of Flyash Concrete and Flyash Fiber Reinforced Concrete
The present Experimental investigation is to study the Mechanical Properties of the Fly ash concrete reinforced with steel fibers. The concrete composite comprises of steel fibers in different percentages and partial replacement of cement in different proportions. Steel fibers varied from 0%, 0.5%, 1% and 1.5% by weight of cement and replacement of fly ash varied from 0%, 10%, 20%, 30% and 40% ...
متن کاملExperimental Investigation on Impact Resistance of Flyash Concrete and Flyash Fiber Reinforced Concrete
The present Experimental investigation is to study the Impact Resistance of the Fly ash concrete reinforced with steel fibers. The concrete composite comprises of steel fibers in different percentages and partial replacement of cement in different proportions. Steel fibers varied from 0%, 0.5%, 1% and 1.5% by weight of cement and replacement of fly ash varied from 0%, 10%, 20%, 30% and 40% by w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2013
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.78.1195