International Personal Dosimeter Intercomparison.
نویسندگان
چکیده
منابع مشابه
Development of Personal Dosimeter Using Electronic Dose Conversion Method
Personal dosimeters based on PIN detectors have been widely used because of their simplicity and real time operation. In this paper, the optimal filter thickness and material designed by the Monte Carlo method is 1.0 mm Al plus 0.2 mm Cu. From the results of radiation characteristic analyses, the developed dosimeter has good performance when it is compared with the other conventional those as d...
متن کاملA Personal Dosimetry Intercomparison Study in Asian and Pacific Region
The IAEA/RCA (Regional Cooperative Agreement) project to strengthen and harmonize radiation protection infrastructures in Asian and Pacific region started in 1988. The number of the RCA member countries is 17 at present. In the early stages of the project, there was little information on the status of radiation protection and their technical abilities of radiation protection measurements in RCA...
متن کاملInternational Field Intercomparison of Atmospheric Mercury Measurement Methods
To determine the extent of comparability of sampling and analytical procedures for atmospheric mercury (Hg) being used by different scientific groups around the world and hence the compatibility of measurement results, the Atmospheric Environment Service (AES) co-ordinated a field intereomparison study in Windsor, Ontario, over a period of 5 days' during Sept./Oct.,1993. This study brought toge...
متن کاملActive Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...
متن کاملDevelopment of a colorimetric personal dosimeter for nitrogen dioxide. AMRL-TR-68-104.
A personal colorimetric dosimeter for nitrogen dioxide has been developed. Detector strips are prepared by dipping Eastman Chromagram Sheet, Type K301R2, in a solution of diphenylamine and oxalic acid in methanol. When dry, the strips can be used to estimate the concentration-time product to which an individual has been exposed. The strips are sensitive to heat and light. Nitrogen dioxide devel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 1993
ISSN: 1884-4111,0033-8303
DOI: 10.3769/radioisotopes.42.11_647