Influence of line current limiting reactor on temporary overvoltage of 500 kV transmission line

نویسندگان

چکیده

Abstract In order to limit the temporary overvoltage, method of series current limiting reactor in line is often used power grid overvoltage. The parameters reactance directly affect level 50Hz installation a changes positive and zero sequence impedance line, which has an impact on overvoltage line. Installing 500 kV Line’s studied by using electromagnetic transient calculation software EMTP. simulation results show that Line can be reduced adding reactor.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the Line Parameters in Transmission Line Fault Location

In the paper, two fault location algorithms are presented for transmission lines which use the line parameters to estimate the distance to the fault. The first algorithm uses only the measurements from one end of the line and the positive and zero sequence parameters of the line, while the second one uses the measurements from both ends of the line and only the positive sequence parameters of t...

متن کامل

the influence of the neo-platonic concept of poetic imagination on wordsworth’s poetry

بر اساس نظریه افلاطون در باره شعر خلاقیت هنری مورد انتقاد قرار گرفته است. نظریه کلی در مورد شعر این بود که شعر از ظواهرتقلید میکند و نه حقیقت. چون سایه ای از حقیقت است. اما با پیدایش فلسفه نو افلاطونی، انتقاتات قبلی در مورد شعر و شاعری اصلاح شد. فلوطین در کتاب انئید، اساس خلق هنری را بر محور مُثل افلاطونی قرار داد. وی باور داشت که هنر مندان در خلق آثار هنری، تحت تاثیر مُثل افلاطونی بوده و عوالمی ...

On-Line Windows Scheduling of Temporary Items

In this paper we study on-line windows scheduling (WS) of temporary items. In a broadcasting system, there are some broadcast channels, each can broadcast one item in one time unit. Upon the arrival of an item with a window w, where w is a positive integer, the item has to be scheduled on a channel such that it will be broadcasted in the channel at least once every w time units until its depart...

متن کامل

Detection and classification of faults on 220 KV transmission line using wavelet transform and neural network

Along with other electrical components, the transmission line suffers from the unexpected failures due to various faults. Protecting of transmission lines is one of the important tasks to safeguard electric power systems. For safe operation of EHVAC transmission line systems, the protection to detect, classify, locate accurately and clear the fault as fast as possible to maintain stability in t...

متن کامل

Current Directional Protection of Series Compensated Line Using Intelligent Classifier

Current inversion condition leads to incorrect operation of current based directional relay in power system with series compensated device. Application of the intelligent system for fault direction classification has been suggested in this paper. A new current directional protection scheme based on intelligent classifier is proposed for the series compensated line. The proposed classifier uses ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2023

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2592/1/012062