Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.
نویسندگان
چکیده
منابع مشابه
Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.
The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella, P. aeruginosa, and a heterotrophic plate count (HPC) at 36 °C was performed from June to Octob...
متن کاملPrevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legion...
متن کاملLegionella spp. in Puerto Rico cooling towers.
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable o...
متن کاملLegionella adelaidensis, a new species isolated from cooling tower water.
A Legionella-like organism (strain 1762-AUS-E) was isolated from a cooling tower of an air-conditioning system in Adelaide, South Australia, Australia. The isolate was presumptively identified as a Legionella strain by its growth requirement for L-cysteine and its cellular branched-chain fatty acids. Strain 1762-AUS-E was serologically distinct in the slide agglutination test with absorbed anti...
متن کاملIsolation of Legionella pneumophilia from cooling tower water by filtration.
Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.