In response to "positive end-expiratory pressure valve malfunctioning detected by capnographic and airway pressure waveform"
نویسندگان
چکیده
منابع مشابه
Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملPositive end-expiratory pressure.
PURPOSE OF REVIEW In the last 2 years, several reports have dealt with recruitment/positive end-expiratory pressure (PEEP) selection. Most of them confirm previous results and few add new information. RECENT FINDINGS It has been definitely confirmed that opening pressures are different throughout the acute respiratory distress syndrome lung parenchyma, ranging from 5-10 up to 30-40 cmH2O. The...
متن کاملAnalysis of heart rate variability in individuals subjected to different positive end expiratory pressure levels using expiratory positive airway pressure
INTRODUCTION The increase in the number of studies has led to greater security in the application of this method and the determination of its effectiveness in adults.. The purpose of the present study was to evaluate heart rate variability in healthy individuals submitted to different levels of positive expiratory pressure using an expiratory positive airway pressure (EPAP) device. MATERIAL A...
متن کاملAirway mechanosensor behavior during application of positive end-expiratory pressure.
BACKGROUND Positive end-expiratory pressure (PEEP) is commonly used in clinical settings. It is expected to affect the input from slowly adapting pulmonary stretch receptors (SARs), leading to altered cardiopulmonary functions. However, we know little about how SARs behave during PEEP application. OBJECTIVES Our study aimed to characterize the behavior of SARs during PEEP application. METHO...
متن کاملA proximal system for positive end-expiratory pressure (PEEP) and continuous positive airway pressure (CPAP).
A proximal positive end-expiratory pressure (PEEP) and continuous positive airway pressure (CPAP) system was constructed by the simple addition of a venturi T-piece proximal to the exhalation limb of a breathing circuit. The level of PEEP or CPAP was determined by the amount of flow powering the venturi. This system can provide positive pressure in excess of 40 cm H2O without the need for check...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Cardiac Anaesthesia
سال: 2015
ISSN: 0971-9784
DOI: 10.4103/0971-9784.148332