Improving molecular radiotherapy dosimetry using anthropomorphic calibration

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry

BACKGROUND Patient-specific absorbed dose calculations for molecular radiotherapy require accurate activity quantification. This is commonly derived from Single-Photon Emission Computed Tomography (SPECT) imaging using a calibration factor relating detected counts to known activity in a phantom insert. METHODS A series of phantom inserts, based on the mathematical models underlying many clini...

متن کامل

Pediatric radiation dosimetry for positron-emitting radionuclides using anthropomorphic phantoms.

PURPOSE Positron emission tomography (PET) plays an important role in the diagnosis, staging, treatment, and surveillance of clinically localized diseases. Combined PET/CT imaging exhibits significantly higher sensitivity, specificity, and accuracy than conventional imaging when it comes to detecting malignant tumors in children. However, the radiation dose from positron-emitting radionuclide t...

متن کامل

Radiotherapy dosimetry using a commercial OSL system.

A commercial optically stimulated luminescence (OSL) system developed for radiation protection dosimetry by Landauer, Inc., the InLight microStar reader, was tested for dosimetry procedures in radiotherapy. The system uses carbon-doped aluminum oxide, Al2O3:C, as a radiation detector material. Using this OSL system, a percent depth dose curve for 60Co gamma radiation was measured in solid water...

متن کامل

Multimodality Imaging for Pre-Therapeutic Molecular Radiotherapy Dosimetry

The treatment of cancer with radiopharmaceuticals is expanding rapidly, in terms of both the numbers of patients treated and the range of treatments offered (Carlsson et al. 2003). An increasing number of radiopharmaceuticals are now being introduced to the clinic and there is a strong potential for this modality to play a larger role in cancer management alongside surgery, external beam radiot...

متن کامل

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physica Medica

سال: 2019

ISSN: 1120-1797

DOI: 10.1016/j.ejmp.2019.01.013