Improved bacteriophage-bacteriocin applicator.
Teflon spaghetti tubing was placed over the metal needles of the dispensing head of the Accu-Drop multidropper, thus preventing the delivery of multiple drops. A metal plate was drilled so that 25 cartridges could be positioned to inoculate simultaneously 25 compartments in a divided petri dish.
متن کاملBacteriophage and bacteriocin typing scheme for Clostridium difficile.
The study of the epidemiology of infection with Clostridium difficile would be aided by a way to type individual bacterial isolates. We therefore sought bacteriophages for use in typing. With mitomycin C exposure (3 micrograms/ml), filtrates from 10 strains of C. difficile had plaque-forming lytic activity on other C. difficile strains. Individual phage were passaged and made into high-titer st...
متن کاملImproved generalized transducing bacteriophage for Caulobacter crescentus.
Caulobacter phage phi Cr30T, a temperature-sensitive derivative of the lytic, generalized transducing phage phi Cr30, was isolated as a double temperature-sensitive recombinant in a cross between phi Cr30ts1 and phi Cr30ts2, phi Cr30T mediated generalized transduction of Caulobacter crescentus at frequencies comparable to those of phi Cr30 and eliminated the requirement for irradiation of trans...
متن کاملDosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing.
PURPOSE Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not...
متن کاملUse of tetrazolium for improved resolution of bacteriophage plaques.
Most phages form plaques which, when prepared by the agar-layer technique (M. H. Adams, Bacteriophages, Interscience Publishers, Inc., New York, 1959), are sufficiently pronounced to permit their accurate enumeration under appropriate conditions of illumination. Other phages, however, are difficult to detect and enumerate because their plaques are small or excessively turbid, or both. Phage 83,...