Improved acetabular fracture diagnosis after training in a CT-based method
نویسندگان
چکیده
منابع مشابه
Charcot arthropathy after acetabular fracture.
Three middle-aged patients with diabetes sustained fractures of the acetabulum which were treated by open reduction and internal fixation. In each, rapid dissolution of the femoral head occurred with minimal discomfort, typical of a Charcot arthropathy. The patients had no other evidence of neuropathic arthropathy. Charcot changes may occur after high-energy trauma in patients with diabetes.
متن کاملA novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملan unusual combination of acetabular and pelvic fracture: is this a new subtype of acetabular fracture?
conclusions we recognized this type of fracture and treated it similarly to both column fractures. we recommend that the classification of acetabular fractures be modified to include this type of fracture. introduction acetabular fractures are a common problem among young males. an acetabular fracture with disruption of the joint surface, if untreated, will rapidly lead to post-traumatic osteoa...
متن کاملSubchondral fracture of the femoral head after acetabular fracture: a case report
INTRODUCTION Preventing post-traumatic osteoarthritis is a challenging problem following acetabular fracture. Progressive osteoarthritis is considered to be caused by an irregular articular surface of the acetabular roof or cartilage injury, but little is known about the pathogenesis of collapse of the femoral head after acetabular fracture. We report a case of post-traumatic osteoarthritis aft...
متن کاملLaparoscopic Acetabular Fracture Fixation after Three-dimensional Modelling and Printing
Current surgical treatment of acetabular fractures is open reduction and internal fixation and requires a large incision resulting in considerable blood loss and a potentially long duration of recovery. We report a case of an acetabular fracture that received laparoscopic internal fixation after three-dimensional (3D) modelling and printing of the acetabulum. A 43 year old male fell from a heig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopaedics & Traumatology: Surgery & Research
سال: 2017