IMPLEMENTATION OF TRS-398 PROTOCOL IN ROUTINE CALIBRATION OF LINAC BY DETERMINATION OF SLAB PHANTOM ON WATER PHANTOM CORRECTION FACTOR

نویسندگان

چکیده

The water phantom is used for LINAC calibration to measure absorbed dose radiation. Practically, it requires a long preparation time and considered less efficient. To increase efficiency, the medical physics team in hospital uses slab as tool. Consequently, correction factor crucial define equivalence of doses resulted from phantom. measurement was performed according IAEA TRS-398 dosimetry protocol with cylindrical ionization chamber detector 6 MV photon beam electron beams Elekta Synergy Platform 154029 MeV, 8 10 12 MeV energy variations. field size 30 cm x cm. Based on protocol, calculated based absolute photons beam, are 1.0018; 0.9995; 0.9979; 1.0041 1.0068, respectively. As result, radiation measured by calibrated using has an equivalent amount

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study on slab-wooden dust-slab phantom for the development of thorax phantom

Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom.  Materials and Methods: Th...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

Ice-Water Phantom Localisation for Diffusion Calibration

When multiple scanners are used to acquire diffusion MR image data from the same patient (even on the same day), there is no guarantee that identical settings will result in comparable images of a specific organ and region. Despite this, for clinical use, any software developed to compute the apparent diffusion coefficient (ADC) must be expected to give equivalent results. What is needed is a p...

متن کامل

investigation of effective parameters on the rigidity of light composite diaphragms (psscb) by fem

در این رساله با معرفی سقف های psscb متشکل از ترکیب ورق های فولادی ذوزنقه ای و تخته های سیمانی الیافی به عنوان سقف های پیش ساخته (سازگار با سیستم سازه ای قاب های فولادی سبک) به بررسی پارامترهای موثر بر صلبیت سقف، پرداخته می شود. در تحقیق حاضر ابتدا به مدل سازی دو نمونه سقف آزمایش شده، به روش اجزاء محدود با استفاده از نرم افزار تحلیلی abaqus ver 6.10 پرداخته شده است. نمونه های ساخته شده تحت اعما...

determination of olanzapine and thiourea using electrodes modified by dna and film of copper-cobalt hexacyanoferrate & investigation of electro-oxidation of some catechol derivatives in the presence of 4-phenylsemicarbazid

چکیده هدف از این کار بررسی الکترواکسیداسیون کتکول و مشتقات آن در حضور 4-فنیل سمی کاربامازید بوده است اکسیداسیون کتکولها ترکیبات نا پایدار کینونها را تولید می کنند که این ترکیبات می تواند در واکنش مایکل بعنوان پذیرنده نوکلئوفیل عمل نمایند. در ادامه اکسایش کتکولهای (a-c1) را درحضور 4-فنیل سمی کاربامازید در محلول آب/استونیتریل (90/10)بوسیله ولتامتری چرخه ای و کولن متری در پتانسیل ثابت مورد بررسی ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Spektra: jurnal fisika dan aplikasinya

سال: 2022

ISSN: ['2541-3392', '2541-3384']

DOI: https://doi.org/10.21009/spektra.072.03