IMPLANTABLE DEFIBRILLATOR LEAD EXTRACTION WITH OPTIMISED STANDARD EXTRACTION TECHNIQUES
نویسندگان
چکیده
منابع مشابه
Implantable defibrillator lead extraction with optimized standard extraction techniques
BACKGROUND Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. METHODS We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction...
متن کاملProphylactic lead extraction at implantable cardioverter-defibrillator generator change.
BACKGROUND Current implantable cardiac devices have a finite battery life of ≈3 to 7 years for implantable cardioverter-defibrillators. It is current practice to reuse all properly functioning intravascular leads. We tested the hypothesis that a strategy of prophylactic lead removal at the time of device change would be superior under some conditions to the current practice of lead reuse. MET...
متن کاملPacemaker and defibrillator lead extraction.
Surgically implanted cardiac devices play an important role in the treatment of heart disease. In the 50 years since the first pacemaker was implanted, technology has improved dramatically, and these devices have saved or improved the quality of countless lives. Pacemakers treat slow heart rhythms by increasing the heart rate or by coordinating the heart’s contraction for some heart failure pat...
متن کاملAn Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques
BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...
متن کاملMulticenter experience with extraction of the Sprint Fidelis implantable cardioverter-defibrillator lead.
OBJECTIVES This study was undertaken to determine the safety and feasibility of extraction of the Sprint Fidelis (Medtronic, Minneapolis, Minnesota) lead. BACKGROUND The reported failure rate of the Sprint Fidelis defibrillator lead has increased to a range greater than initially appreciated with emerging evidence of an accelerating rate of fracture. At present, consensus guidelines continue ...