IMPLANTABLE DEFIBRILLATOR LEAD EXTRACTION WITH OPTIMISED STANDARD EXTRACTION TECHNIQUES

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable defibrillator lead extraction with optimized standard extraction techniques

BACKGROUND Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. METHODS We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction...

متن کامل

Prophylactic lead extraction at implantable cardioverter-defibrillator generator change.

BACKGROUND Current implantable cardiac devices have a finite battery life of ≈3 to 7 years for implantable cardioverter-defibrillators. It is current practice to reuse all properly functioning intravascular leads. We tested the hypothesis that a strategy of prophylactic lead removal at the time of device change would be superior under some conditions to the current practice of lead reuse. MET...

متن کامل

Pacemaker and defibrillator lead extraction.

Surgically implanted cardiac devices play an important role in the treatment of heart disease. In the 50 years since the first pacemaker was implanted, technology has improved dramatically, and these devices have saved or improved the quality of countless lives. Pacemakers treat slow heart rhythms by increasing the heart rate or by coordinating the heart’s contraction for some heart failure pat...

متن کامل

An Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques

BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...

متن کامل

Multicenter experience with extraction of the Sprint Fidelis implantable cardioverter-defibrillator lead.

OBJECTIVES This study was undertaken to determine the safety and feasibility of extraction of the Sprint Fidelis (Medtronic, Minneapolis, Minnesota) lead. BACKGROUND The reported failure rate of the Sprint Fidelis defibrillator lead has increased to a range greater than initially appreciated with emerging evidence of an accelerating rate of fracture. At present, consensus guidelines continue ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Heart

سال: 2012

ISSN: 1355-6037,1468-201X

DOI: 10.1136/heartjnl-2012-302920n.7