Impact of respiratory motion on breast tangential radiotherapy using the field-in-field technique compared to irradiation using physical wedges

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of respiratory motion on breast tangential radiotherapy using the field-in-field technique compared to irradiation using physical wedges

BACKGROUND This study aimed to evaluate whether the field-in-field (FIF) technique was more vulnerable to the impact of respiratory motion than irradiation using physical wedges (PWs). PATIENTS AND METHODS Ten patients with early stage breast cancer were enrolled. Computed tomography (CT) was performed during free breathing (FB). After the FB-CT data set acquisition, 2 additional CT scans wer...

متن کامل

the impact of using inspirational quotes on abstract vocabulary recall

the present study is an attempt to investigate the potential impact of inspirational quotes on improving english abstract vocabulary recall. to achieve this goal, a multiple choice language proficiency test of 60 items including vocabulary and grammar component was administered to a sample of 63 second-semester male and female students whose age ranged between 17 to 22 and they were studying en...

15 صفحه اول

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques

To evaluate the dosimetric impact of respiratory breast motion and daily setup error on whole breast irradiation (WBI) using three irradiation techniques; conventional wedge (CW), field-in-field (FIF) and irregular surface compensator (ISC). WBI was planned for 16 breast cancer patients. The dose indices for evaluated clinical target volume (CTV(evl)), lung, and body were evaluated. For the ant...

متن کامل

Determination of the optimal method for the field-in-field technique in breast tangential radiotherapy

Several studies have reported the usefulness of the field-in-field (FIF) technique in breast radiotherapy. However, the methods for the FIF technique used in these studies vary. These methods were classified into three categories. We simulated a radiotherapy plan with each method and analyzed the outcomes. In the first method, a pair of subfields was added to each main field: the single pair of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiology and Oncology

سال: 2014

ISSN: 1581-3207,1318-2099

DOI: 10.2478/raon-2013-0032