Impact of range shifter material on proton pencil beam spot characteristics
نویسندگان
چکیده
منابع مشابه
Evaluation of the range shifter model for proton pencil‐beam scanning for the Eclipse v.11 treatment planning system
Existing proton therapy pencil-beam scanning (PBS) systems have limitations on the minimum range to which a patient can be treated. This limitation arises from practical considerations, such as beam current intensity, layer spacing, and delivery time. The range shifter (RS) - a slab of stopping material inserted between the nozzle and the patient - is used to reduce the residual range of the in...
متن کاملGolden beam data for proton pencil-beam scanning.
Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PBS delivery system. The combination of a priori quantification and measurements...
متن کاملDynamic Delivery Planning in Iba Proton Pencil Beam
Pencil Beam Scanning is a dynamic beam delivery system developed for proton therapy. The radiation field necessary to reach in a fast and robust way a prescribed 3D dose distribution is obtained by accurately controlling both the extraction of the beam from a 235 MeV accelerator and the motion of the beam spot thanks to scanning magnets. This paper focuses on the trajectory planning aspect of t...
متن کاملA parameter study of pencil beam proton dose distributions for the treatment of ocular melanoma utilizing spot scanning.
The results of Monte Carlo calculated dose distributions of proton treatment of ocular melanoma are presented. An efficient spot scanning method utilizing active energy modulation, which also minimizes the number of target spots was developed. We simulated various parameter values for the particle energy spread and the pencil beam diameter in order to determine values suitable for medical treat...
متن کاملComparing proton treatment plans of pediatric brain tumors in two pencil beam scanning nozzles with different spot sizes
Target coverage and organ-at-risk sparing were compared for 22 pediatric patients with primary brain tumors treated using two distinct nozzles in pencil beam scanning (PBS) proton therapy. Consecutive patients treated at our institution using a PBS-dedicated nozzle (DN) were replanned using a universal nozzle (UN) beam model and the original DN plan objectives. Various cranial sites were treate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2015
ISSN: 0094-2405